4.4
Mounting the inlet and outlet
Installing connection cables
The connection cables can be mounted at various positions
on the system tank:
Item
Connection
2
DN 100
6
DN 100
8
DN 50 or DN 100
9
Scoring surface, maximal DN 150.
A. Inlet at the socket (2)
Saw off the socket at the indicated cutting edge.
B. Inlet at the socket (6)
Saw off the socket at the indicated cutting edge.
C. Inlet at the socket (8)
Saw off the socket at the indicated cutting edge. (DN 50
or DN 100)
D. Inlet on the surface (9)
The inlet can be connected on the surfaces.
Make sure that
- Backflowing wastewater does not get into the inlet pipe.
- The lower edge of the connection cable is not lower than
135 mm (from the bottom of the tank)
Use a suitable hole saw and seal for the pipe penetration
(max. DN 150) (available as accessories).
Art. no.
500100
Hole saw for DN 100/125/150
500101
Hole saw for DN 50/70/100
850117
Seal for pipe penetration, DN 100
850118
Seal for pipe penetration, DN 125
850119
Seal for pipe penetration, DN 150
34 / 148
Description
Installation and operating instructions
Fig.: Aqualift L Mono
Fig.: Aqualift L Duo
016-880