WARNING
Transport risk / system's own weight!
Check the weight of the system / system components (see "Technical data", page 31).
Pay attention to correct lifting and ergonomic factors.
Standing under overhead loads is prohibited.
The cover plate may only be transported tightly lashed down on the pallet.
NOTICE
Contaminated surface!
The system and surroundings can be contaminated by germs.
Do not store or consume any food in the same room.
Avoid touching the surface, remove visible dirt.
After work is complete, wash your hands.
Prescribed personal protective equipment!
Always use personal protective equipment during installation, maintenance and disposal work on the system.
Protective clothing
Protective gloves
Safety footwear
Face protection
CAUTION
Pumps can start up unexpectedly.
Before undertaking maintenance or repair work on the system, switch it off or disconnect it from the power supply.
The pump must never run dry or in slurping operation; the multi-vane impeller and pump housing must always be
flooded up to at least the minimum immersion depth.
The pump may not be used if the pressure pipe is not connected.
The pump builds up a pumping pressure/excess pressure.
Operating and maintenance instructions must be kept available at the product.
NOTICE
Improper cleaning
Plastic components can become damaged or brittle
Only clean plastic components with water and a pH-neutral cleaning agent.
2.3
Intended use
The system must be used only for the pumping of normal household faecal wastewater, and not for combustible or explosive
liquids or solvents.
WARNING
Use of the system in a potentially explosive environment (ATEX) is not permitted.
All modifications or attachments that are carried out without the express and written permission of the manufacturer, the use
of non-genuine spare parts and repairs carried out by companies or persons not approved by the manufacturer will lead to a
loss of warranty.
The control unit is equipped with a protective circuit to protect the system's electrical components from damage in case of
possible voltage peaks.
This does not protect against lightning.
If such requirements exist, an appropriate protective device must be installed on site.
2.4
Product description
The Aqualift L lifting station is designed for pumping wastewater with and without sewage and is equipped with one or two
submersible pump(s) and a backflow preventer.
The collection tank made of permanently resistant polymer (PE) has a closed pump tank with universal connection options
and a screw-on access cover.
The system is controlled by a user-friendly control unit that is supplied.
The switching signals of the float switch are processed electronically in the control unit. When the switch-on level has been
reached, the pump-off function is activated. Pumping is ended when the level has fallen again by an appropriate amount.