16. Technical data
Ambient conditions
Storage temperature:
Ambient temperature:
Air humidity:
Sauna control unit
Dimensions:
Voltage rating/three-phase 3N:
Frequency:
Power rating/heater:
Current rating per phase/heater:
Switching capacity/vaporizer:
Switched current/vaporizer:
Switching capacity/additional output (dimmable)*
Switching capacity/additional output (switchable)*
Switched current/additional output:
Status output:
Rated voltage:
Protection class (protected against splashing water):
Connection to the mains supply as fixed wiring (fixed connection)
Light
Power rating:
Fuse:
Fan
Power rating:
Fuse:
Setting ranges
Temperature:
Humidity:
The maximum humidity that can be set depends on the temperature of the
sauna. The higher the sauna temperature, the lower the maximum humidity
level which can be set.
* The additional output has no excess temperature fuse. For this reason, only
intrinsically safe devices should be operated using the additional output.
p. 46/48
-25°C to +70°C
-10°C to +40°C
max. 95%
307 x 175 x 57 mm
400 V AC
50 Hz
3 x 3.5 kW
16 A
3.5 kW
16 A
500 W
3.5 W
16 A
24 V/200 mA
230 V
IPX4
100 W
1A T
100 W
1A T
30°C to 110°C
0 % to 100 %