Installation instructions, only for experts
4.2. Installing the heater sensor F1 with overheat cut-out
Note the following points when installing the heater sensor:
● The heater sensor must be installed on the rear of the heater, above the
middle of the sauna heater. A distance of about 15 cm from the ceiling of the
cabin must be maintained.
● The heater sensor must be installed in such a way that it is not affected by
inflowing air.
To install the heater sensor, perform the following steps (see Fig.3):
1. Route the two 2-pole heater sensor cables in the wall of the sauna cabin
to the installation location of the heater sensor and affix the heater sensor
cables using cable clips.
2. Pull the two half-shells 1 of the heater sensor apart.
3. Connect the four connections for the heater sensor cable 5 in accordance
with the Fig.3.
4. Place the connection panel 2 crossways (as shown in Fig.3) in the heater
sensor half-shells.
5. Place the two half-shells together, screw them together using two cross-
head screws 3 (9 mm) and check whether the heater sensor has been
securely closed.
6. Install the heater sensor on the rear of the heater using the two wood screws
6 supplied (16 mm).
1
Heater sensor half-shells
2
Connection panel
3
Cross-head screws (9 mm)
4
Heater sensor
5
Heater sensor leads
6
Wood screws (16 mm)
Fig.3
Installing the
heater sensor
p. 15/48
EN