Installation instructions, only for experts
4.3. Installing bench sensor F2 (optional)
The bench sensor must be installed on the wall of the cabin above the rear bench
seat. A distance of about 15 cm from the ceiling of the cabin must be maintained.
To install the bench sensor, carry out the following steps:
1. Route the 2-pole bench sensor lead in the wall of the sauna cabin to the
mounting location of the bench sensor and affix the bench sensor leads
using cable clips.
2. Pull the two half-shells of the bench sensor apart.
3. Connect the two connectors for the bench sensor lead to the two middle
terminals on the connection panel.
4. Place the connection panel crossways in the bench sensor half-shells.
5. Place the two half-shells together and screw them together using the two
cross-head screws (9 mm).
6. Check whether the bench sensor has been securely closed.
7. Install the bench sensor on the wall of the sauna cabin using the two sup-
plied wood screws (16 mm). Maintain a clearance of 15 cm from the roof
of the sauna cabin.
4.4. Installing humidity/temperature sensor FTS2 (optional,
PRO C3 only)
The humidity/temperature sensor must be installed on the wall of the cabin above
the rear bench seat. A distance of approx. 15 cm from the ceiling of the cabin
must be maintained.
To install the humidity and temperature sensor, perform the following steps:
1. Route the 5-pole sensor cable in the wall of the sauna cabin to the mount-
ing position of the humidity/temperature sensor and affix the sensor leads
using cable clips.
2. Install the humidity/temperature sensor to the wall of the sauna cabin using
the two supplied wood screws (16 mm). Maintain a clearance of 15 cm to
the roof of the sauna cabin.
4.5. Installing the foil sensor (optional)
If an infrared heat plate is to be connected to an additional output, the P-ISX-FF
foil sensor must be used.
● When installing the foil sensor, observe the operating instructions for the
infrared heating plates.
● Use of a foil sensor must be activated in the technician menu (see 8.2. Settings