Installation instructions, only for experts
4. Installation
4.1. Installing the sauna control unit
ATTENTION!
Damage to the unit
The sauna control unit is resistant to splashing water, but direct contact with
water could still damage it.
● Install the sauna control unit in a dry place at which a maximum humidity of
95% is not exceeded.
ATTENTION!
Interference can impair signal transmission
● Route all sensor cables separately from other mains cables and control cables.
● Protect cables with only one layer of insulation by using a conduit (double
insulation).
Observe the following points when installing the sauna control unit:
● The sauna control unit must be installed outside the sauna cabin or in accord-
ance with the recommendation issued by the sauna manufacturer.
● The ambient temperature must be within a range spanning -10°C to +40°C.
● The sensors may only be connected using the sensor cables supplied with
the unit, which are heat-resistant up to 150°C.
The sensor leads may be extended under the following conditions:
● A silicon cable resistant to temperatures up to 150 °C is used.
● The minimum cross-sectional of the cable is 0.5 mm
● The heater sensor cables may NOT be longer than 10 m.
p. 13/48
2
.
EN