Installation instructions, only for experts
2. Turn the top knob to the temperature symbol (position A – see point 9.2 on
page 31).
► The temperature symbol flashes.
► In the top display, "SEnB" appears.
3. Press the bottom knob several times until "ISt2" appears in the top display.
4. Turn the bottom knob to the left or right to activate or deactivate the function.
Activating vaporizer single mode (PRO C3 only)
The vaporizer is factory set so that it can only be operated together with the
heating system. To operate the vaporizer on its own without the heating system,
this function must be activated. Perform the following steps:
1. Open the technician menu (see 26).
2. Turn the top knob to the humidity symbol (position B – see point 9.2 on
page 31).
► The humidity symbol flashes.
► In the top display, "SIn" appears.
► "OFF" appears in the bottom display (deactivated vaporizer single mode.)
3. Turn the bottom knob to the right.
► "On" appears in the bottom display (activated vaporizer single mode)
Setting the duration of the post-drying program (PRO C3 only)
The standard setting for the maximum duration of the post-drying program is
30 min. If you wish to change this setting, perform the following steps:
1. Open the technician menu (see 26).
2. Turn the top knob to the humidity symbol (position B)
► The humidity symbol flashes.
► In the top display, "SIn" appears.
3. Press the bottom knob.
► "t30" appears in the bottom display.
4. Turn the bottom knob (selection 0–60; 0 = post-drying program switched off;
60 = maximum duration in minutes)
p. 28/48