Installation instructions, only for experts
Activating/deactivating phase alignment
Phase alignment is activated or deactivated using the function selection switch 3.
● The function selection switch 3 is set to the ON position as standard. Phase
alignment is therefore activated.
● If you wish to deactivate phase alignment, place the function selection switch
3 in the OFF position.
Remote start release
Function selection switch 4 can be used to select the function of the remote
start output
(please see EN 60335-2-53).
● Function selection switch 4 is set to the OFF position as standard. The remote
start is activated using "Standby for remote control".
● If you want to enable the remote start output for various devices (e.g. coin-op-
erated unit, remote start system, door monitoring), set function selection
switch 4 to the ON position.
Setting the light operating mode
The light for the sauna cabin can either be dimmed or switched on and off. The
dimmer switch function is activated or deactivated using the function selection
switch 5.
● The function selection switch 5 is set to the ON position as standard. The
dimmer switch function is therefore activated.
► To change the dimming characteristic, see "Changing the light dimming
characteristic" on page 29.
● If you wish to deactivate the dimmer function for the sauna cabin light, place
the function selection switch 5 in the OFF position.
Status output
The function selection switch 7 can be used to help to decide whether the status
output should be activated during sauna mode or during the post-drying program.
Activation during the post-drying program allows the vaporizer to be drained
automatically when a combi heater with an auto refill function is being used.
● Function selection switch 7 is set to the OFF position as standard. The status
output is therefore activated during sauna mode.
● If you wish to activate the status output during the post-drying program, place
the function selection switch 7 in the ON position.
p. 25/48
EN