Installation instructions, only for experts
Displaying the heater temperature in single-sensor mode
In single-sensor mode, the sauna control unit only displays the set temperature
as standard. The actual temperature is not displayed. Should the sauna control
unit display the temperature above the heater (F1) as an actual temperature in
single-sensor mode, it must be activated in the technician menu.
1. Open the technician menu (see page 26)
2. Activate the single-sensor mode (see page 26).
► The top display shows "SEnB".
► The bottom display shows "OFF".
3. Press the bottom knob.
► In the top display, "dISP" appears.
► "SEt" appears in the bottom display (only the set temperature is displayed
in single-sensor mode.)
4. Turn the bottom knob to the left.
► "SEnS" appears in the bottom display (the heater temperature (F1 sen-
sor) is displayed as the actual temperature in the single-sensor mode)
Decreasing the maximum temperature to 105 °C
The preset temperature can be set to between 30 °C and 110 °C as standard. If
you wish to decrease the maximum temperature from 110 °C to 105 °C, perform
the following steps:
1. Open the technician menu (see 26).
2. Turn the top knob to the temperature symbol (position A – see point 9.2 on
page ).
► The temperature symbol flashes.
► In the top display, "SEnB" appears.
3. Press the bottom knob until "tHI" appears in the top display.
► In the bottom display, "110" appears.
4. Turn the bottom knob to the left.
► "105" appears in the bottom display (maximum temperature set to 105°C)
Activating simultaneous display of the temperature and humidity
To activate simultaneous display of the temperature and humidity, carry out the
following steps:
1. Open the technician menu (see 26).
p. 27/48