room (indirect aeration and ventilation), at provided that the flow is free through permanent
openings communicating with the outside.
The adjacent room may not be used as a garage, for storing combustible materials or for any other
activity involving a fire hazard, bathroom, bedroom or common room in the building.
Ventilation is considered adequate if the room is equipped with air inlets as shown in the table :
Device categories
Fireplaces
Stoves
Cookers
Installation in premises where there is a risk of fire is prohibited. Installation in residential premises
where, in all cases, the negative pressure measured at the time of installation between the indoor
and outdoor environment is greater than 4 Pa .
All national, regional, provincial and municipal laws and standards in force in the country where the
appliance is installed must be observed.
Percentage of net opening cross-
section in relation to the flue gas
outlet cross-section of the appliance
50%
50%
50%
EN
Minimum net value of
ventilation duct opening
2
200 cm
2
200 cm
2
200 cm