Télécharger Imprimer la page

United States Stove Company 5770E Mode D'emploi page 9

Publicité

Test Conditions Summary
Testing conditions for all runs fell within allowable specifications of ASTM E2779 and
ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below.
Ambient (°F)
Runs
Pre
Post
1
66
71
Appliance Operation and Test Settings
The appliance was operated according to procedures as described in the Operations
Manual, found in Appendix B submitted with this report. Detailed run information can be
found in Appendix A submitted with this report.
Settings & Run Notes
Pre-Burn
HR 5, Damper open 50%
Run 1
(max)
Page | 9
Average
Relative
Barometric
Humidity (%)
Pressure
(In. Hg.)
Pre
Post
19.0
14.4
29.76
Maximum Segment
HR 5
Damper open 50% (max)
Project # 24-284
Preburn
Test Fuel
Test Fuel
Fuel
Weight
Moisture
Weight
(lbs)
(lbs)
3.0
13.3
Test Run
Medium Segment
HR 3
Damper open 50%
Model: 5770E
Test Run
Time
(%DB)
(Min)
2.1%
360
Minimum Segment
HR 1
Damper full closed (min)

Publicité

loading