Test Procedures and Equipment
All Sampling and analytical procedures were performed by Aaron Kravitz. All procedures
used are directly from ASTM E2779 and ASTM E2515. See the list below for equipment
used. See Appendix C submitted with this report for calibration data.
Equipment List:
Equipment ID# Equipment Description
189 Mettler Toledo 3'x3' floor scale w/digital weight indicator
053 APEX XC-60 Digital Emissions Sampling Box A
054 APEX XC-60 Digital Emissions Sampling Box B
203 APEX XC-50-DIR Digital Emissions Sampling Box C
055 APEX Ambient sampling box
215 NI Temperature DAQ
057 California Analytical ZRE CO2/CO/O2 IR ANALYZER
109A/B Troemner 100mg/200mg Audit Weights
107 Sartorius Analytical Balance
097 10 lb audit weight
095 Anemometer
217 Microtector
CC505834 Gas Analyzer Calibration Span Gas
CC341544 Gas Analyzer Calibration Mid Gas
Barometric pressure data was taken from local National Weather Service station KPDX.
As PFS and KPDX are at the same altitude, the correction for altitude per ASTM E2515
6.1.2 is 1:1.
Page | 7
Project # 24-284
Model: 5770E