24-284 Run 1 Data.xlsm
PM
– Average particulate emissions for full integrated test run, g/hr
R
ASTM E2779 equation (5)
PM
= 60 (E
R
Where,
Sample Calculation:
E
(Dual train average) =
T
PM
= 60 x (
R
PM
R
PFS-TECO
/θ)
T
E
= Total particulate emissions, grams
T
θ = Total length of full integrated test run, min
6.59 g
θ =
360 min
6.59 / 360 )
=
1.10
g/hr