Télécharger Imprimer la page

United States Stove Company 5770E Mode D'emploi page 62

Publicité

24-284 Run 1 Data.xlsm
M
– Weight of test fuel burned during test run segment i , dry basis, kg
BSidb
ASTM E2779 equation (2)
M
= (MS
BSidb
Siwb
Where,
M
=
SSiwb
M
=
ESiwb
Sample Calculation (from medium burn rate segment):
FM = 2.15 %
M
= 9.8
SSiwb
M
= 4.8
ESiwb
0.4536 = Conversion factor from lbs to kg
M
= [(
BSidb
M
= 2.24 kg
BSidb
PFS-TECO
- M
)(100/(100 + FM))
ESiwb
weight of test fuel in hopper at start of test run segment i , wet basis, kg
weight of test fuel in hopper at end of test run segment i , wet basis, kg
lbs
lbs
9.8
x 0.4536) - (
4.8
x 0.4536)] (100/(100 +
Page 3 of 18
2 )

Publicité

loading