INSTALLATION
FLOOR PROTECTION
This heater must have a non-combustible floor protector
(UL1618 ember protection) installed beneath it if the
floor is of combustible material.
US: The floor pad or non-combustible surface should be
large enough to cover at least the area under the product
and 6" (152 mm) beyond the front and beyond each
side of the fuel loading and ash removal openings. Floor
protection must extend under and 2" (51 mm) to each
side of the chimney tee for an interior vertical installation.
Canada: Require a minimum of 475 mm [18"] beyond the
front of the unit and 203 mm [8"] beyond each side of the
unit. A Floor Protector of 1/4 inch thick is recommended
for this installation.
A
B
Floor Protector
Floor Protector
A
Rear
B
Side
C
Front
D
Rear
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home, and alcove applications in
accordance with the clearances given in this manual.
For safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in clearance
to combustibles may only be done by means approved by
a regulatory authority.
B
C
D
1"
25 mm
USA
6"
153 mm
CAN
8"
203 mm
USA
6"
153 mm
CAN
18"
475 mm
2"
50 mm
E
H
TABLE 1 CLEARANCES
E Back wall to unit
PARALLEL
F Sidewall to flue
G Sidewall to top edge of unit
CORNER
H Adjacent wall to unit
OUTSIDE
AIR
INSTALLING IN A MOBILE HOME)
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT CAP
UNDER CERTAIN CONDITIONS AND CAN AFFECT
THE PERFORMANCE OF YOUR STOVE, AS WELL
AS, OTHER UNFORESEEABLE ISSUES.
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.
Installation instructions are supplied with the air intake
kit.