24-284 Run 1 Data.xlsm
Q
– Average gas flow rate in dilution tunnel, dscf/hr
sd
ASTM E2515 equation (3)
Where:
3600
=
B
=
ws
A
=
T
=
std
P
=
s
T
=
s
P
=
std
Sample calculation:
Q
=
3600 x (1 - 0.02) x
sd
Q
= 12146.7 dscf/hr
sd
PFS-TECO
Conversion from seconds to hours (ASTM method uses 60 to convert in minutes)
Water vapor in gas stream, proportion by volume; assume 2%
Cross sectional area of dilution tunnel, ft
Standard absolute temperature, 528 °R
Absolute average gas static pressure in dilution tunnel, = P
Absolute average gas temperature in the dilution tunnel, °R; (°R = °F + 460)
Standard absolute pressure, 29.92 in Hg
18.44 x 0.1963
Page 7 of 18
2
+ P
bar
29.76 +
528
x
x
92.0
+ 460
, in Hg
g
-0.09
13.6
29.92