24-284 Run 1 Data.xlsm
BOX B TEST DATA - ASTM E2779 / ASTM E2515
Client:
USSC
Model:
5770E
Run #:
1
Gas Meter
Elapsed
Sample
3
Time (min)
Rate (cfm)
(ft
)
352
61.561
353
61.736
354
61.908
355
62.082
356
62.258
357
62.432
358
62.605
359
62.778
360
62.954
Avg/Tot
62.954
PFS-TECO
Particulate Sampling Data
Orifice dH
Meter
(in H
O)
Temp (°F)
2
0.176
2.96
102.2
0.175
2.96
102.3
0.172
2.96
102.2
0.174
2.95
102.2
0.176
2.95
102.3
0.174
2.95
102.3
0.173
2.95
102.2
0.173
2.95
102.1
0.176
2.95
102.3
0.175
3.04
95
Job #:
24-284
Tracking #:
190
Technician:
AK
Date:
5/3/2024
Meter
Pro.
Vacuum
Filter (°F)
Rate (%)
(in Hg)
2.99
-
2.54
-
2.5
-
2.63
-
2.64
-
2.51
-
2.96
-
2.59
-
2.7
99
2.17
100
Page 32 of 33
Flue Gas Data
Flue Draft
CO
(%)
2
(in H
O)
2
79
-0.037
1.37
79
-0.037
3.81
79
-0.036
2.30
79
-0.041
2.59
79
-0.038
3.54
79
-0.041
3.33
79
-0.035
3.67
79
-0.036
1.24
79
-0.037
2.16
3.66
CO (%)
0.02
0.00
0.00
0.00
0.00
0.00
0.00
0.05
0.00
0.01

Publicité