Sommaire des Matières pour United States Stove Company 5770E
Page 1
United States Stove Company Project # 24-284 Model: 5770E AKA: AP5770E, VG5770E, US5770E, KP5770E, KP5770E-W, CGPS2100, BHPS30, DH3000 Type: Pellet-Fired Room Heater June 12, 2024 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet Heaters (EPA ALT-146) Contact: Mr.
Page 2
Project # 24-284 Model: 5770E Revision History June 12, 2024– Original Issue Page | 2...
Page 3
Project # 24-284 Model: 5770E Contents Affidavit ................................. 4 Introduction ..............................5 Notes ................................. 5 Pellet Heater Identification and Testing ......................6 Test Procedures and Equipment ........................7 Results ................................8 Summary Table ............................8 Test Run Narrative ............................ 8 Run 1 ..............................
Page 4
Affidavit PFS-TECO was contracted by United States Stove Company (USSC) to provide testing services for the 5770E Pellet-Fired Room Heater per ASTM E2779, Determining PM Emissions from Pellet Heaters. All testing and associated procedures were conducted at PFS-TECO’s Portland Laboratory on 5/3/2024. PFS-TECO’s Portland Laboratory is located at 11785 SE Highway 212 –...
Page 5
Model: 5770E Introduction United States Stove Company of South Pittsburg, TN, contracted with PFS-TECO to perform EPA certification testing on the 5770E Pellet-Fired Room Heater. All testing was performed at PFS-TECO’s Portland Laboratory. Testing was performed by Mr. Aaron Kravitz.
Page 6
Model: 5770E Pellet Heater Identification and Testing • Appliance Tested: 5770E • Serial Number: N/A – Prototype Unit; PFS Tracking #0190 • Manufacturer: United States Stove Company • Catalyst: No • Heat exchange blower: Integral • Type: Pellet Stove • Style: Free Standing •...
Page 7
Project # 24-284 Model: 5770E Test Procedures and Equipment All Sampling and analytical procedures were performed by Aaron Kravitz. All procedures used are directly from ASTM E2779 and ASTM E2515. See the list below for equipment used. See Appendix C submitted with this report for calibration data.
Page 8
Higher Heating Value efficiency of 78% and a CO emission rate of 0.10 g/min. The calculated first hour particulate emission rate was 2.4 g/hr. The US Stove Model 5770E Pellet-Fired Room Heater meets the 2020 PM emission standard of ≤ 2.0 g/hr per CFR 40 part 60, §60.532 (b).
Page 9
Project # 24-284 Model: 5770E Test Conditions Summary Testing conditions for all runs fell within allowable specifications of ASTM E2779 and ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below. Average Preburn Relative Test Fuel...
Page 10
BHPS30, and DH3000. All of these models are differentiated for branding purposes only, and are identical in all respects that may affect emissions performance to the 5770E. Air Introduction System: A variable speed combustion fan forces air into the firebox through holes in the bottom of the firepot.
Page 11
Project # 24-284 Model: 5770E Appliance Front Appliance Left Page | 11...
Page 13
Project # 24-284 Model: 5770E Test Fuel Properties Test fuel used was Lignetics Pellet Fuel, a PFI Certified Premium Pellet Brand. A sample of pellets was sent to Twin Ports Testing for analysis, see report below. Page | 13...
Page 15
Project # 24-284 Model: 5770E Sampling Locations and Descriptions Sample ports are located 14 feet downstream from any disturbances and 2 feet upstream from any disturbances. Flow rate traverse data was collected 12 feet downstream from any disturbances and 4 feet upstream from any disturbances. (See below).
Page 16
Project # 24-284 Model: 5770E Sampling Methods ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 6 inches in diameter. All sampling conditions per ASTM E2515 were followed. No alternate procedures were used. Page | 16...
Page 17
Project # 24-284 Model: 5770E Analytical Methods Description All sample recovery and analysis procedures followed ASTM E2515 procedures. At the end of each test run, filters, O-Rings and probes were removed from their housings, dessicated for a minimum of 24 hours, and then weighed in pairs at 6 hour intervals to a constant weight per ASTM E2515-11 Section 10.
Page 19
Project # 24-284 Model: 5770E List of Appendices The following appendices have been submitted electronically in conjunction with this report: Appendix A – Test Run Data, Technician Notes, and Sample Analysis – Page 20 Non- CBI PDF Appendix B – Labels and Manuals- Page 87 Non-CBI PDF Appendix C –Equipment Calibration Records- Page 157 Non-CBI PDF...
Page 21
PELLET TEST DATA PACKET ASTM E2779/E2515 Run 1 Data Summary Client: USSC Model: 5770E Job #: 24-284 Tracking #: Test Date: 5/3/2024 5/15/2024 Techician Signature Date PFS-TECO...
Page 22
24-284 Run 1 Data.xlsm TEST RESULTS - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Burn Rate Summary High Burn Rate (dry kg/hr) 1.54 Medium Burn Rate (dry kg/hr) 1.121...
Page 23
24-284 Run 1 Data.xlsm Overall Pellet Test Efficiency Results Manufacturer: USSC Model: 5770E Date: 05/03/24 Run: 1 Control #: 24-284 Test Duration: 360 Output Category: Integrated Test Results in Accordance with CSA B415.1-10 HHV Basis LHV Basis Overall Efficiency 77.7% 83.3%...
Page 24
24-284 Run 1 Data.xlsm Max Burn Rate Segment Efficiency Results Manufacturer: USSC Model: 5770E Date: 05/03/24 Run: 1 Control #: 24-284 Test Duration: 60 Output Category: Maximum Test Results in Accordance with CSA B415.1-10 HHV Basis LHV Basis Overall Efficiency 80.0%...
Page 25
24-284 Run 1 Data.xlsm Medium Burn Rate Segment Efficiency Results Manufacturer: USSC Model: 5770E Date: 05/03/24 Run: 1 Control #: 24-284 Test Duration: 120 Output Category: Medium Test Results in Accordance with CSA B415.1-10 HHV Basis LHV Basis Overall Efficiency 77.1%...
Page 26
24-284 Run 1 Data.xlsm Minimum Burn Rate Segment Efficiency Results Manufacturer: USSC Model: 5770E Date: 05/03/24 Run: 1 Control #: 24-284 Test Duration: 180 Output Category: Minimum Test Results in Accordance with CSA B415.1-10 HHV Basis LHV Basis Overall Efficiency 76.7%...
Page 27
24-284 Run 1 Data.xlsm DILUTION TUNNEL & MISC. DATA - ASTM E2779 / E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Test Start Time: 9:15 Date: 5/3/2024 High Burn End Time (min): Medium Burn End Time (min):...
Page 28
24-284 Run 1 Data.xlsm PELLET STOVE PREBURN DATA - ASTM E2779 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: Technician: Date: 5/3/2024 Recording Interval (min): Run Time (min): Average: -0.051 Flue Draft (in Elapsed Time Scale Weight Change Flue (°F)
Page 30
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 31
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 32
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 33
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 34
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 35
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 36
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 37
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 38
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 39
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 40
24-284 Run 1 Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: 1 Technician: AK Date: 5/3/2024 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data...
Page 41
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 42
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 43
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 44
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 45
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 46
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 47
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 48
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 49
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 50
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 51
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 52
24-284 Run 1 Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: Run #: Technician: Date: 5/3/2024 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft...
Page 53
24-284 Run 1 Data.xlsm LAB SAMPLE DATA - ASTM E2515 Client: USSC Job #: 24-284 Model: 5770E Tracking #: 190 Run #: Technician: AK Date: 5/3/2024 Sample ID Tare, mg Final, mg Catch, mg 255.8 Filters G01000 250.8 246.7 G01001 242.0...
Page 54
ASTM E2779 Wood Heater Run Sheets Client: USSC Job Number: 24-284 Tracking #: 190 Model: 5770E Run Number: 1 Test Date: 5/3/2024 Pellet Heater Control Settings High Burn Rate Settings: HR 5, Damper open 50% Medium Burn Rate Settings: HR 3, Damper open 50%...
Page 55
5770E This conditioning was performed at a medium heat setting Scale Wt./lb Room Ambient °F Flue gas °F @ 8 ft. Date-Time Reading (min) 4/16/2024 6:35 71.2 68.16 224.67 4/16/2024 6:50 70.6 68.74 240.56 4/16/2024 7:05 69.9 69.03 251.33 4/16/2024 7:20 69.2...
Page 60
Equations and Sample Calculations – ASTM E2779 & E2515 Client USSC Model: 5770E Tracking #: Run: Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
Page 61
24-284 Run 1 Data.xlsm – Weight of test fuel burned during test run, dry basis, kg ASTM E2779 equation (1) = (M )(100/(100 + FM)) Where, average fuel moisture of test fuel, % dry basis weight of test fuel in hopper at start of test run, wet basis, kg weight of test fuel in hopper at end of test run, wet basis, kg Sample Calculation: FM = 2.15 %...
Page 62
24-284 Run 1 Data.xlsm – Weight of test fuel burned during test run segment i , dry basis, kg BSidb ASTM E2779 equation (2) = (MS )(100/(100 + FM)) BSidb Siwb ESiwb Where, weight of test fuel in hopper at start of test run segment i , wet basis, kg SSiwb weight of test fuel in hopper at end of test run segment i , wet basis, kg ESiwb...
Page 63
24-284 Run 1 Data.xlsm BR – Average dry burn rate over full integrated test run, kg/hr ASTM E2779 equation (3) 60 M θ Where, = Total length of full integrated test run, min θ Sample Calculation: = 5.90 = 360 θ...
Page 64
24-284 Run 1 Data.xlsm – Average dry burn rate over test run segment i , kg/hr ASTM E2779 equation (4) 60 M BSidb θ Where, Total length of test run segment i , min θ Sample Calculation (from medium burn rate segment): 2.24 BSidb θ...
Page 65
24-284 Run 1 Data.xlsm – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equations (9) Where: Adjustment factor for center of tunnel pitot tube strav , ASTM E2515 Equation (1) placement, Fp = scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent...
Page 66
24-284 Run 1 Data.xlsm – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3) Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in dilution tunnel, = P...
Page 67
24-284 Run 1 Data.xlsm – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6) Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
Page 68
24-284 Run 1 Data.xlsm – Total Particulate Matter Collected, mg ASTM E2515 Equation (12) Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train A: Using equation for Train B: Page 9 of 18 PFS-TECO...
Page 69
24-284 Run 1 Data.xlsm - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf ASTM E2515 equation (13) Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train A:...
Page 70
24-284 Run 1 Data.xlsm – Total Particulate Emissions, g ASTM E2515 equation (15) − Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr Total time of test run, minutes θ...
Page 71
24-284 Run 1 Data.xlsm PR - Proportional Rate Variation ASTM E2515 equation (16) Where: θ = Total sampling time, min θ = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith” time interval, dcf = Volume of gas sample as measured by dry gas meter, dcf = Average gas velocity in the dilution tunnel during the "ith"...
Page 72
24-284 Run 1 Data.xlsm – Average particulate emissions for full integrated test run, g/hr ASTM E2779 equation (5) = 60 (E /θ) Where, = Total particulate emissions, grams θ = Total length of full integrated test run, min Sample Calculation: (Dual train average) = 6.59 g θ...
Page 73
24-284 Run 1 Data.xlsm – Average particulate emission factor for full integrated test run, g/dry kg of fuel burned ASTM E2779 equation (6) Where, = Total particulate emissions, grams = Weight of test fuel burned during test run, dry basis, kg Sample Calculation: (Dual train average) = 6.59 g...
Page 74
24-284 Run 1 Data.xlsm Stack Loss Efficiency and CO emissions calculations are done in accordance with CSA B415.1, using the password protected excel spreadsheet provided with the test standard. No alterations or alternative calculations are used for determining efficiency or CO emissions. The following pages are a sample of the calculations page from the B415.1 Spreadsheet (V2_4 - Dated April 15, 2010).
Page 75
Manufacturer: USSC Model: 5770E Air Fuel Ratio (A/F) Date: 05/03/24 Overall Heating Efficiency: 77.72% Dry Molecular Weight (M 29.27 Run: Note: In the “Input data”, "Calc. % O ", "Fuel Properties", Combustion Efficiency: 99.50% Dry Moles Exhaust Gas (N 1157.58 and “Mass Balance”...
Page 76
Moisture Content M Combustion Efficiency: 99.50% Moisture of Wood (wet basis): Dry kg : 5.90 Initial Dry Weight Wt (kg): Total Input (kJ): 118,379 112,277 (Btu) 5.90 Total Output (kJ): 92,007 87,264 (Btu) Moisture Content Dry 2.15 Efficiency: 77.72% 44.13 Total CO (g): 35.93 Load Weight (kg):...
Page 77
SUMS AVERAGE SUMS 2916.17 2725.33 293.64 45980.62 181079.22 20381.06 791197.82 -105618.32 536132.89 20088.10 4125.32 24555.44 -1224.45 25779.9 94004.4 -1255.5 35.9 -28.5 Change - Ambient to Stack Temperature Room Total Energy Losses (kJ/kg of Dry Fuel) Flue Gas Constituent Temp Flue Gas Constituent Loss Total Chemical...
Page 81
Twin Ports Testing, Inc. 1301 North 3rd Street Superior, WI 54880 715-392-7114 800-373-2562 715-392-7163 www.twinportstesting.com Report No: USR:W224-0189-01 Analytical Test Report Issue No: Client: PFS-TECO Signed: 11785 SE Hwy 212, Ste 305 Clackamas, OR 97015 Attention: Sebastian Button Katy Jahr Chemistry Lab Supervisor PO No: 5/13/2024...
Page 82
According to the information provided, you seek an alternative test method for use when conducting testing on the United States Stove Company, Model KP5517 pellet heater. Currently, as required by section 60.534(a)(l)(i) of Subpart AAA, a manufacturer has the option to test their appliance in accordance with 40 CFR part 60, Appendix B, Method 28R for a crib fuel appliance or ASTM E2779-10 “Standard Test Method for Determining Particulate Matter Emissions from...
Page 83
the position(s) as needed to achieve a burn rate that is ≤ 50% of the maximum burn rate.” Table 1 of ASTM E2779-10 also notes that the Medium Burn Rate Category test must be ≤ 50% of the maximum burn rate. The memorandum states that this is incorrect as it assumes that zero is the other bound for determining half of the maximum burn rate, and that the correct approach in determining the Medium Burn Rate Category should be at a level below 50% of the span between the Maximum Burn Rate and the Low Burn Rate (a non-zero value).
Page 84
Group Leader Measurement Technology Group Angelina Brashear – EPA/OAQPS/AQAD Chuck French – EPA/OAQPS/SPPD Rafael Sanchez – EPA/OECA Robert Scinta – EPA/OECA Michael Toney – EPA/OAQPS/AQAD Nathan Topham – EPA/OAQPS/SPPD John Voorhees – United States Stove Company Chet Wayland – EPA/OAQPS/AQAD...
Page 85
02/02/2022 MEMORANDUM SUBJECT: Appropriate calculation of Medium Burn Rate Category in ASTM E-2779 Testing FROM: Steffan Johnson Digitally signed by STEFFAN Group Leader STEFFAN JOHNSON Date: 2022.02.02 Measurement Technology Group JOHNSON 08:28:07 -05'00' Air Quality Assessment Division Robert Scinta, P.E. Chief, Air Branch Monitoring, Assistance, and Media Programs Division Office of Compliance, Office of Enforcement and Compliance Assurance...
Page 86
The correct application of this requirement would be to determine the Medium Burn Rate Category at a level below 50% of the span between the Maximum Burn Rate and the Low Burn Rate (a non-zero value). Ergo, the correct calculation for finding that midpoint of 50% is defined For example, if the Maximum Burn rate of an appliance is 1.79 kg/hr and the minimum is 1.23 kg/hr, the method would currently place the 50% requirement at 0.895 kg/hr.
Page 88
• Replace the defective part free of charge. Parts and/or service replacements made under the terms of this warranty are warranted only for the remaining period of the original heater warranty. • Replace the heater free of charge. Should the heater be replaced by United States Stove Company “free of charge”, all further warranty obligations are thereby met.
Page 89
IMPORTANT We congratulate you on your selection of United States Stove Company and its products. As the oldest solid fuel manufacturer in the United States (since 1869), the United States Stove Company is very proud of its products, service, employees, and satisfied customers.
Page 90
• Remplacer l’appareil de chauffage sans frais. Si l’appareil de chauffage doit être remplacé par United States Stove Company « sans frais », tous les engagements au titre de cette garantie seront respectés.
Page 91
GARANT Le garant de ce dossier est United States Stove Company, PO Box 151, 227 Industrial Park Road, South Pittsburg, Tennessee 37380. Numéro de téléphone : (800)-750-2723. Enregistrez votre produit en ligne au www.usstove.com. Conservez votre preuve d’achat, documentée sous forme de facture ou de reçu, en cas de réclamation.
Page 92
United States Stove Company (“USSC”) or an authorized dealer.
Page 93
• Replace the defective part free of charge. Parts and/or service replacements made under the terms of this warranty are warranted only for the remaining period of the original heater warranty. • Replace the heater free of charge. Should the heater be replaced by United States Stove Company “free of charge”, all further warranty obligations are thereby met.
Page 94
IMPORTANT We congratulate you on your selection of United States Stove Company and its products. As the oldest solid fuel manufacturer in the United States (since 1869), the United States Stove Company is very proud of its products, service, employees, and satisfied customers.
Page 101
à bois d'une manière incompatible avec les instructions d'utilisation dans le manuel du propriétaire. regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner's manual. MODEL / MODÈLE : 5770E 0.10 TEXT HEIGHT Non-Combustible Floor Protection / Dégagements Combustibles: Dans Une Résidence ou Une Maison Mobile...
Page 102
Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a manufactured or mobile home. This manual describes the installation and operation of the USSC, 5770E wood heater. This heater meets the 2020 US Environmental Protection Agency’s wood pellet emissions limits for wood heaters sold after May 15, 2020.
Page 150
Manufacturedby United States Stove Co. for : World Marketing of America, Inc. 12256 William Penn Hwy Mill Creek, PA 17060 DO NOT REMOVE OR COVER THIS LABEL / NE PAS RETIRER OU COUVRIR CETTE ÉTIQUETTE 1.50 12.00 0.25 HOLES DESCRIPTION SCALE SIZE UNITED STATES STOVE COMPANY TOLERANCES SEE NOTE ± .005" EXCEPT ESTABLISHED 1869 DWN BY DECIMAL BLANK NUMBER...
Page 151
à bois d'une manière incompatible avec les instructions d'utilisation dans le manuel du propriétaire. regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner's manual. MODEL / MODÈLE : 5770E 0.10 TEXT HEIGHT Non-Combustible Floor Protection / Dégagements Combustibles: Dans Une Résidence ou Une Maison Mobile...
Page 152
227 Industrial Park Road • South Pittsburg, TN 37380 Phone: 423-403-4031 • Web: www.breckwell.com DO NOT REMOVE OR COVER THIS LABEL / NE PAS RETIRER OU COUVRIR CETTE ÉTIQUETTE 1.50 12.00 0.25 HOLES DESCRIPTION SCALE SIZE UNITED STATES STOVE COMPANY TOLERANCES SEE NOTE ± .005" EXCEPT ESTABLISHED 1869 DWN BY DECIMAL BLANK NUMBER...
Page 153
Owner’s Instruction and Operation Manual Model Number: CGPS2100 5770 Report #: F20-578 Certified to ASTM E1509-2022 and CAN/ULC S627:2023 Mobile Home / Transportable Building Approved * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. 854127-1902N Save These Instructions In A Safe Place For Future Reference.
Page 154
SPECIFICATIONS Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a manufactured or mobile home. This manual describes the installation and operation of the Comfort Glow, CGPS2100, 5770 wood heater. This heater meets the 2020 US Environmental Protection Agency’s wood pellet emissions limits for wood heaters sold after May 15, 2020.
Page 155
INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-776-9425 COMMISSIONING CHECKLIST This checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference. Failure to install and commission according to the manufacturer’s instructions and complete this checklist will invalidate the warranty.
Page 156
INSTALLATION CAUTION: SAFETY NOTICE BURNING FUEL CREATES CARBON MONOXIDE AND • IF THIS STOVE IS NOT PROPERLY INSTALLED, A CAN BE HAZARDOUS TO YOUR HEALTH IF NOT HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF PROPERLY VENTED. FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. •...
Page 157
INSTALLATION of the fuel loading and ash removal openings. Floor protection must extend under and 2” (51 mm) to each side of the chimney tee for an interior vertical installation. Canada: Require a minimum of 475 mm [18”] beyond the front of the unit and 203 mm [8”] beyond each side of the unit.
Page 158
INSTALLATION SECURING APPLIANCE TO THE FLOOR VENTING REQUIREMENTS Use the designated holes to secure the unit to the floor. WARNING: • INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.
Page 159
INSTALLATION PELLET VENT TYPE C. Minimum 3-foot (0.91m) clearance from any adjacent building. A certified 3-inch or 4-inch type “PL” pellet vent exhaust D. Minimum 7-foot (2.13m) clearance from any grade system must be used for installation and attached to the when adjacent to public walkways.
Page 160
INSTALLATION THROUGH THE WALL INSTALLATION a 3” (76 mm) clearance should be maintained from the (RECOMMENDED INSTALLATION) outside wall and a clean out tee should be placed on the pipe with a 90-degree turn away from the house. At this point, a 3ft (0.91m) (minimum) section of pipe should be added with a horizontal cap, which would complete the installation.
Page 161
OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED HOW YOUR HEATER WORKS • Once the heater reaches a set temperature, the room fan will come on. Your pellet heater operates on a timer based auger fuel feed system, that is controlled by a digital circuit board. DISPLAY The fuel is delivered from the auger into a burn pot, which •...
Page 162
OPERATION INSTRUCTIONS 10. Salt water driftwood or other previously salt water Pellets can be screened before being placed in hopper saturated materials; to remove most fines. 11. Unseasoned wood; or • Binders – Some pellets are produced with materials to hold the together, or “bind”...
Page 163
OPERATION INSTRUCTIONS This pellet stove has been certified by the US EPA to OPEN meet strict 2020 guidelines. To Ensure this unit produces the optimal minimal emissions, it is critical to follow the following guidelines. To achieve a “high burn” your stove should be set on setting 5 with the damper 50% closed.
Page 164
OPERATION INSTRUCTIONS 2. If the combustion blower fails, an air pressure switch CAUTION: will automatically shut down the auger. • THE HOPPER AND STOVE TOP WILL BE HOT NOTE: Opening the stove door for more than 30 seconds DURING OPERATION; THEREFORE, YOU SHOULD during operation will cause enough pressure change to ALWAYS USE SOME TYPE OF HAND PROTECTION activate the air switch, shutting the fuel feed off.
Page 165
MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED FLY ASH CAUTION: This accumulates in the horizontal portion of an exhaust • FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS run. Though non-combustible, it may impede the normal INDICATED CAN RESULT IN POOR PERFORMANCE, SAFETY HAZARDS, FIRE, AND EVEN DEATH.
Page 166
MAINTENANCE out the chimney, exposure to the gases in closed or from your U.S. Stove dealer. If glass is broken, follow these confined areas can be dangerous. Make sure you stove removal procedures: gaskets and chimney joints are in good working order 1.
Page 167
MAINTENANCE MAINTENANCE SCHEDULE Monthly or Daily Weekly as needed Use the following as a guide under average use conditions. Gaskets around door and door glass should be inspected Burn Pot Stirred Empty and repaired or replaced when necessary. Combustion Brushed Chamber Ashes Check...
Page 168
TROUBLE SHOOTING GUIDE When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 1) poor fuel;...
Page 169
TROUBLE SHOOTING GUIDE If there is no current going to the combustion blower, check all wire Control board not sending power to combustion connections. If all wires are properly connected, you have a bad blower. control board. There should be a 5-volt current (approximately) going to the air switch Control board not sending power to air switch.
Page 170
TROUBLE SHOOTING GUIDE Display is Flashing “E4” Possible Causes Possible Remedies: (Unplug stove first when possible) The air inlet, burnpot, interior combustion air Follow all cleaning procedures in the maintenance section of the chambers, combustion blower, or exhaust pipe owner’s manual. are blocked with ash or foreign material.
Page 171
TROUBLE SHOOTING GUIDE STOVE FEEDS PELLETS, BUT WILL NOT IGNITE Possible Causes Possible Remedies: (Unplug stove first when possible) Push the air damper in closer to the side of the stove for startup. In some situations it may be necessary to have the damper completely Air damper open too far for ignition.
Page 172
TROUBLE SHOOTING GUIDE STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes Possible Remedies: (Unplug stove first when possible) Wait for the stove to cool for about 30 - 45 minutes. Locate the High Limit High limit switch has tripped or is thermodisc and press the reset button on the back of it.
Page 175
REPAIR PARTS Part # Description Part # Description 892183 Main Weldment 892198 Warm Air Outlet Grill 83538 Shaft Collar - Ignitor Tube 80915 RTD Temperature Probe 892184 Hopper 892203 Hinge Pin 892185 Auger Housing Weld. 80941 PCBA, Controller 892186 Plate, Auger Bushing 892200 Vented Side Panel, Right 892187 Auger 892201 Vented Side Panel, Left...
Page 176
SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
Page 177
LIMITED WARRANTY Limited Warranty (Wood and Pellet Stoves) Warranty Period Branded Solid Fuel Burning Products Component Parts Labor Pellet Wood Component Parts Covered by this Warranty Cast Iron Components, Steel liners, Retainers, Gaskets, Firebrick and All 2 Years from Electrical Components. All Parts including handles, external enameled Date of Purchase components and other material except as covered by Warranty conditions, Warranty Exclusions, and Warranty Limitations listed.
Page 178
LIMITED WARRANTY • WMAI’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Information is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consideration must be given to appliance location and configuration, environmental conditions, insulation and air tightness of the structure.
Page 215
Owner’s Instruction and Operation Manual Model Number: DH3000 Report #: F20-578 Certified to ASTM E1509-2022 and CAN/ULC S627:2023 Mobile Home / Transportable Building Approved * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. Save These Instructions In A Safe Place For Future Reference. SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
Page 216
Manuel d’instructions et d’utilisation du propriétaire Numéro De Modèle: DH3000 Rapport #: F20-578 Certifié conforme aux normes ASTM E1509-2022 and CAN/ULC S627:2023 Homologué Mobil Home / Bâtiment Transportable * Toutes les images de ce manuel sont à des fins d’illustration uniquement. Le produit réel peut varier. Conservez ces instructions dans un endroit sûr pour référence ultérieure.
Page 217
Owner’s Instruction and Operation Manual Model Number: BHPS30 Report #: F20-578 Certified to ASTM E1509-2022 and CAN/ULC S627:2023 Mobile Home / Transportable Building Approved * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. Save These Instructions In A Safe Place For Future Reference. SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
Page 218
Manuel d’instructions et d’utilisation du propriétaire Numéro De Modèle: BHPS30 Rapport #: F20-578 Certifié conforme aux normes ASTM E1509-2022 and CAN/ULC S627:2023 Homologué Mobil Home / Bâtiment Transportable * Toutes les images de ce manuel sont à des fins d’illustration uniquement. Le produit réel peut varier. Conservez ces instructions dans un endroit sûr pour référence ultérieure.
Page 221
Dry Gas Meter Calibration Manufacturer: APEX Model: XC-60 Lab ID #: Serial #: 1902130 Calibration Date: 2/1/2024 Calibration Expiration: 8/1/2024 Barometric Pressure: 29.34 in. Hg Ref. Std. DGM Equipment Used: Thermometer Barometer Manometer Manufacturer: Apex Aquatech Dwyer Model: SK25DA NI-9213 DBX2 Lab ID#: 47 Calibration Expiration Date: 4/17/2024...
Page 222
Dry Gas Meter Calibration Manufacturer: APEX Model: XC-60 Lab ID #: Serial #: 1902133 Calibration Date: 2/1/2024 Calibration Expiration: 8/1/2024 Barometric Pressure: 29.34 in. Hg Ref. Std. DGM Equipment Used: Thermometer Barometer Manometer Manufacturer: Apex Aquatech Dwyer Model: SK25DA NI-9213 DBX2 Lab ID#: 47 Calibration Expiration Date: 4/17/2024...
Page 223
Report and Certificate of Calibration 33086-203325-4525 Customer PO#: 1109 Report #: Customer Name: PFS TECO Customer Address: 1507 Matt Pass City: Cottage Grove State: WI Zip: 53527 Contact: Ethan Frederick Service Address: 11785 SE Highway 212, Suite 305 Clackamas, OR 97015 Calibration Standards 10-01442 | Compound Gauge | Fluke | SN: 4582643 | Cal: 01/26/2024 | Due: 01/31/2025 | Vendor: Fluke | Report #: EVL943251 LP-01782 | Thermo-Hygrometer | Comark | SN: 06247790052 | Cal: 01/24/2024 | Due: 01/31/2025 | Range: 122 °F 95 %RH | Report #: 32568-205513-3646...
Page 224
Newport Industries Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01.
Page 225
Report and Certificate of Calibration Report #: 33086-203326-4525 Customer PO#: 1109 Customer Name: PFS TECO Customer Address: 1507 Matt Pass City: Cottage Grove State: WI Zip: 53527 Contact: Ethan Frederick Service Address: 11785 SE Highway 212, Suite 305 Clackamas, OR 97015 Calibration Standards 10-01442 | Compound Gauge | Fluke | SN: 4582643 | Cal: 01/26/2024 | Due: 01/31/2025 | Vendor: Fluke | Report #: EVL943251 LP-01782 | Thermo-Hygrometer | Comark | SN: 06247790052 | Cal: 01/24/2024 | Due: 01/31/2025 | Range: 122 °F 95 %RH | Report #: 32568-205513-3646...
Page 226
Newport Industries Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01.
Page 227
Dry Gas Meter Calibration Manufacturer: APEX Model: XC-60 Lab ID #: Serial #: 1902130 Calibration Date: 2/5/2024 Calibration Expiration: 8/5/2024 Barometric Pressure: 29.39 in. Hg Ref. Std. DGM Equipment Used: Thermometer Barometer Manometer Manufacturer: Apex Aquatech Dwyer Model: SK25DA NI-9213 DBX2 Lab ID#: 47 Calibration Expiration Date: 4/17/2024...
Page 228
Report and Certificate of Calibration Report #: 33086-206391-4525 Customer PO#: 1109 Customer Name: PFS TECO Customer Address: 1507 Matt Pass City: Cottage Grove State: WI Zip: 53527 Contact: Ethan Frederick Service Address: 11785 SE Highway 212, Suite 305 Clackamas, OR 97015 Calibration Standards 13-01811 | Thermocouple Meter/Calibrator | Tegam | SN: 2454186 | Cal: 10/04/2023 | Due: 02/28/2024 | Range: 2400 °F | Report #: 31363-217443-3646 LP-01782 | Thermo-Hygrometer | Comark | SN: 06247790052 | Cal: 01/24/2024 | Due: 01/31/2025 | Range: 122 °F 95 %RH | Report #: 32568-205513-3646...
Page 229
Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Thermocouple LOGGING FUNCTION UUT As UUT As Calibration As Left Expanded Channel Left Left Standard As Found Error Uncertainty± Reading 1 Reading 2 Filter A 0.00 0.60 0.60 0.60 0.60 500.00 500.60 500.60 500.60...
Page 230
Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Thermocouple LOGGING FUNCTION UUT As UUT As Calibration As Left Expanded Channel Left Left Standard As Found Error Uncertainty± Reading 1 Reading 2 0.00 0.00 0.00 0.00 Right 0.00 500.00 500.00 500.00 500.00 0.00...
Page 231
Report and Certificate of Calibration Report #: Customer PO#: 33086-206391-4525-B 1109 Customer Name: PFS TECO Customer Address: 1507 Matt Pass City: State: WI Zip: 53527 Cottage Grove Contact: Ethan Frederick Service Address: 11785 SE Highway 212, Suite 305 Clackamas, OR 97015 Calibration Standards 13-01811 | Thermocouple Meter/Calibrator | Tegam | SN: 2454186 | Cal: 10/04/2023 | Due: 02/28/2024 | Range: 2400 °F | Report #: 31363-217443-3646 LP-01782 | Thermo-Hygrometer | Comark | SN: 06247790052 | Cal: 01/24/2024 | Due: 01/31/2025 | Range: 122 °F 95 %RH | Report #: 32568-205513-3646...
Page 232
Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Thermocouple LOGGING FUNCTION UUT As UUT As Calibration As Left Expanded Channel Left Left Standard As Found Error Uncertainty± Reading 1 Reading 2 0.00 -0.20 -0.20 -0.20 Meter C 0.20 500.00 499.90 499.90 499.90...
Page 236
JJ Calibrations, Inc. Certificate of Calibration 7724 SE Aspen Summit Drive Portland, OR 97266-9217 743892 Certificate Number: Phone 503.786.3005 FAX 503.786.2994 PFS TECO 11785 SE Hwy 212 1033 Suite 305 0723.01 03/08/2021 Order Date: Clackamas, OR 97015 Calibration Authorized By: Property #: Calibrated on: 03/18/2021...
Page 238
Report and Certificate of Calibration Report #: 32664-227238-5 Customer PO#: 1107 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212, Suite 305 City: State: OR Zip: 97015 Clackamas Contact: John Steinert Service Address: 5777 SE International Way Milwaukie, OR 97222 Calibration Standards LP-00397 | Gage Block Set | Mitutoyo | SN: 509020 | Cal: 12/28/2022 | Due: 12/28/2024 | Vendor: BHD Test and Measurement | Report #: 99826 LP-01346 | Thermo-Hygrometer | Comark | SN: 06210350198 | Cal: 02/17/2023 | Due: 02/28/2024 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 28026-67215-4239...