"PPE": It is essential for the operator's
safety that the connector is properly locked as
soon as it is connected to the anchoring device.
GB
After installation, check that the connector(s) of
the fall arrest system(s) align freely in the possi-
ble direction of the operator's fall without risk of
jamming or interference with the body of the an-
choring device (fig. 1, ref. 1) and on the tracrod
anchor base 150Kg (fig. 3).
• Check the condition of all components of the
associated fall arrest system. Refer to the spe-
cific instructions for each component.
• Check the complete fall arrest system.
• Verify that the anchoring device has been pe-
riodically inspected within last 12 months.
Fig. 4, ref. 6.2).
4. Functions and description
The tracrod anchor rod point is an original piece
of equipment which, for the purposes of this
manual, must be used as a personal fall arrest
anchor point. It must only be used on a trac-
rod 150kg anchor base supplied exclusively by
Tractel.
A Tractel® fall arrest anchorage system con-
sists of (fig. 1)
A body (fig. 1, ref. 1)
- Unlocking actuator (fig 1, ref. 2)
- A locking device. (fig 1, ref. 3)
- Two anchoring rings (fig 1, ref. 4), one operator
150kg per ring
- Installation stop (fig 1, ref. 5)
A label indicating the date of the next periodic
review (Fig 4, ref. 6.2).
- This Operation and Maintenance Installation
Manual.
- A warning plate or label (Fig. 4, ref. 6).
Use recommendations (Figure 1):
• The Tractel® fall arrest anchorage sys-
tem
should
only
the installation specifications of the rec-
ommended
fall
(Figure 5)
10
be
used
according
arrest
system
connector
- once connected to the harness anchorage
point, the connector must be at a maximum dis-
tance of 0.9m from the vertical line materialized
by the anchorage (Fig 1 a1)
- The maximum working load of the Tractel® fall
arrest anchorage system is 150 kg per opera-
tor. It can be used by two operators (§ Technical
specifications). It is imperative to ensure, before
use, that all components of the fall arrest system
are compatible with this load by referring to their
respective instructions. If this is not the case, the
maximum load will be that of the element of the
fall arrest system that has the lowest maximum
operating load.
- The tracrod 150kg anchor rod must only be
used with the tracrod 150kg anchor base. This
equipment must only be used to protect people
from falling from a height.
(
•
"WARNING": Under no circumstances
may the Tractel
®
age device be used simultaneously as a fall ar-
rest anchorage point and as a support for the
Tractel
anchorage rod.
®
•
"DANGER": Any other combination of
use is dangerous and prohibited.
5. Installation
5.1 Pre-installation checks
•
Before any installation, the installer must
have this manual in his possession and must
ensure that the tracrod 150kg anchor base is in-
stalled according to the recommendations in this
operating manual. Any other combination of the
150kg tracrod rod, other than the 150kg tracrod
anchor base, is prohibited.
In particular, before any installation, check:
That the fall arrest anchorage device is located
above the operator's displacement plan.
That the installer has the necessary tools to in-
stall the Tractel
®
to
• A 19mm pipe wrench
• A torque wrench equipped with a 19mm socket
• A set of flat keys from size 10 to 24.
tracrod base fall arrest anchor-
anchoring device in particular: