4 Harness Attachment
SRL Materials
Component
Case
Drum
Pawl, Swivel Assembly, Main Spring
Lifeline
Connectors
Energy Absorber
Energy Absorber Pouch
4
Harness Attachment
WARNING!
DO NOT rely on feel or sound to verify proper connector engagement. Ensure the connector is closed before use.
Failure to follow this warning can result in serious personal injury or death.
• Ensure the SRL housing is connected to a suitable anchor point at foot level or above with the appropriate
connecting hardware.
• The V-SHOCK EDGE SRL may be connected to an approved full body harness by feeding the snaphook through the
back D-ring of the harness.
• If utilizing the V-SHOCK EDGE SRL on a ladder system, the user may connect to an approved full body harness by
feeding the snaphook through the front D-ring of the harness.
5
Installation and Use
5.1
Intended Use
SRLs are intended to be used as a connecting element between a full body harness and anchor point. See Section
Product
Specification. A full body harness is the only acceptable body holding device to be used with a SRL. If supplied as
part of a complete system, components shall not be substituted.
For ANSI users: Maximum Arrest force is 1800 lb (8 kN), Average Arrest Force is 1350 lb (6 kN), Maximum Arrest Distance
is 3.5 ft (1.1 m)
WARNING!
SRLs are only to be used for their intended purpose and within their limitations. DO NOT intentionally misuse this
l
product. DO NOT use fall protection equipment for purposes other than those for which it was designed. DO NOT
use fall protection equipment for towing, hoisting, or material handling.
SRLs shall not be altered or added to. No unauthorized repairs, modifications, alterations and/or additions are
l
permitted. Only MSA or persons or entities with written authorization from the manufacturer may make repairs to the
SRL.
RESCUE AND EVACUATION: the user must have a rescue plan and the means at hand to implement it. The plan
l
must take into account the equipment and specific training necessary to affect prompt rescue under all foreseeable
conditions. If the rescue must be performed in a confined space, the provisions of OSHA regulation 1910.146 and
ANSI Z117.1 must be taken into account. It is recommended to provide means for user evacuation without
assistance of others. This will usually reduce the time to get to a safe place and reduce or prevent the risk to
rescuers.
DO NOT rely on feel or sound to verify proper snaphook or carabiner engagement. Ensure that gate and keeper are
l
closed before use.
9
Material
Nylon
Nylon
Steel
7/32" (5.5 mm) DIA Galvanized Steel Cable
Steel
Nylon
Polyester
V-SHOCK® EDGE SRL