SRLs shall be protected from fire, acids, caustic solutions, or temperatures outside the range -40°F to 130°F (-40°C
l
to 54°C).
DO NOT leave the SRL installed in environments which could cause damage or deterioration to the product. Refer to
l
the care details in Section
Examinations.
Instructions shall be retained and provided to all users of SRLs in the language of the destination country, even when
l
resold.
DO NOT exceed the maximum fall arrest forces as specified by governing standards or subsystem components.
l
Use of combinations of components or subsystems, or both, may affect or interfere with the safe function of the
l
components or subsystems. Use only compatible components or subsystems; never add additional length to the
system.
Leading Edge-Specific Product Use
Use in edge situations should only be as a last resort. Leading edge configurations shall only be used after all other
l
hierarchy of controls, including restraint systems and overhead anchorages, have been exhausted.
Avoid working where the lifeline will continuously or repeatedly abrade against sharp, jagged, or abrasive edges.
l
The V-SHOCK EDGE SRL anchorage point shall be at the user's foot level or above.
l
Do not work on the far side of an opening opposite the anchorage point or around corners.
l
Leading edge configurations shall only be used in accordance with local regulations.
l
In leading edge applications with 0 ft (0 m) setback, ensure that setup does not allow housing unit or top connector to
l
contact leading edge in the event of a fall.
Inspection/Removing Product From Service
SRLs that have arrested a fall or are unable to pass an inspection shall be tagged "UNUSABLE" until it has been
l
destroyed and disposed of in accordance with local regulations.
Due to the nature of some fall arrest events, it is possible for the load indicator to not deploy. In the event that a SRL
l
is subjected to fall arrest forces and the load indicator does not deploy, the SRL still must be removed from service
and marked as "UNUSABLE" until it has been destroyed until it has been destroyed and disposed of in accordance
with local regulations.
If the load indicator is deployed, immediately remove the SRL from service and mark it as "UNUSABLE" until it has
l
been destroyed and disposed of in accordance with local regulations
Failure to follow these warnings can result in serious personal injury or death.
3
Product Specification
System Requirements
Component
Anchorage Connector Standard
Harness Standard
Connectors Standard
Retractable Type Fall Arresters
Structure Strength
NOTE: The product may comply with standards shown. See product label for specific compliance information. Those
designated with a certification mark are listed with the corresponding agency as compliant to the applicable standard.
US
8 Cleaning and Storage
and inspection details in Section
ANSI/OSHA
ANSI Z359.18 / OSHA 1926.502, 1910.140
ANSI Z359.11 / OSHA 1926.502, 1910.140
ANSI Z359.12 / OSHA 1926.502, 1910.140
ANSI Z359.14 / OSHA 1926.502, 1910.140
3600 lbs (16 kN) certified 5000 lbs (22.2 kN) non-
certified
V-SHOCK® EDGE SRL
3 Product Specification
7 Pre-Use Checks and Periodic
CSA
CSA Z259.15
CSA Z259.10
CSA Z259.12
CSA Z259.2.2
5000 lbs (22.5 kN)
8