GB
ELIMINATING FAULTS
10
ELIMINATING FAULTS
MALFUNCTION
running.
Green operating light lights up
running.
Green operating light not does
not light up
running.
Red indicator light lights up
means of the remote control.
not rotate the rotor
up pressure in the mortar hose.
However, coating material does
46
POSSIBLE CAUSE
Lance control cable not connected or
damaged
loaded/overheated.
-
Remote control line not connected or
defect.
-
Rotor stuck in stator.
Pump was not lubricated with pump
sliding means.
Coating material "plug" in the mortar
hose. Mortar hose not prerinsed with
cellulose paste.
ELIMINATION
Check control cable
- Plug in the power plug.
- Check the power cable for damage and replace,
-
-
Close material tap and disconnect mains plug.
about 5 minutes.
Connect remote control, check connections, check
remote control line for damage.
(forwards) – "R" (reverse).
Contact Wagner customer service if the problem
cannot be resolved.
Depressurize the mortar hose – set the selector
switch to "R" (reverse).
Pump the coating material back into the con-
tainer.
The mortar hose must be pres-
sureless.
Watch the manometer ––> 0 bar.
Wear safety goggles.
Decouple mortar hose and rinse with water hose.
When the plug has been removed, fill cellulose
paste in the mortar hose. Couple the mortar hose
back on.
Plast Coat 830