Green programming key card

1.
Insert batteries. Make sure the polarity is correct (Fig. 1).
The green and red LEDs flash alternately for several seconds.
Afterwards the green LED flashes.
2.
While the green LED flashes, present the green programming key card
to the external knob at a maximum distance of 2 cm.
The green LED flashes briefly and an acoustic signal is audible to
confirm successful allocation.
Afterwards the red LED flashes.
If the red LED flashes first, do not present the green programming
key card to the external knob. Instead, cancel the procedure,
remove the batteries, and repeat the initial start-up procedure.

Red clearing key card

3.
While the red LED flashes, present the red clearing key card to the
external knob.
The green LED flashes and an acoustic signal is audible to confirm
successful allocation.
Afterwards the electronics switch off automatically.
If errors have occurred during allocation, the initial start-up procedure must
be repeated.
If another error occurs, the Dialock Service must be contacted.

Allocating locking authorisation to a user key card

4.
Present the green programming key card to the external knob.
The red LED flashes briefly and an acoustic signal is audible.
Afterwards the green LED flashes.
5.
Present the user key card that has to be trained to the external knob
within 5 seconds.
The green LED flashes and an acoustic signal is audible.
6.
Remove user key card that has been trained.
The green LED flashes.
Locking authorisation has been allocated to the user key card.