9.6.1.
MENU 1. COMBUSTION MANAGE
This menu manages the combustion parameters. It has
different submenus:
9.6.1.1.
POWER
You can modify the power of the boiler according to
different set ups: Power 1, 2, 3, 4, 5 or A (A=Automatic
combustión). The selected value should be confirmed with
the key
before going out of the menu.
9.6.1.2.
AUGER CALIBRATION
You can increase or decrease the fixed value. The fixed
value from factory is 0 and the range is between -7 to +7.
Consider that each value you modify is equivalent to modify
proportionally 2% each power the value of loading time
(seconds) assigned to the auger motor. The selected value
should be confirmed with the key
the menu.
Consider that as more pellets we load the more power
the boiler provides and more consume of combustible. In
case you see the stove does not burn properly or the mix
combustible/air is not the right one try with this loading
parameter.
9.6.1.3.
SMOKE EXTRACTOR CALIBRATION
You can increase or decrease the fixed value . The fixed
value from factory is 0 and the range is between -7 to +7.
Consider that each value you modify is equivalent to modify
proportionally 5% each power the value of fan speed (rpm)
assigned to the smoke extractor. The selected value should
be confirmed with the key
Consider that as more smoke extractor speed the more
smoke extraction we have but also the more air inlet in the
combustion chamber (larger flame). In case you see the
stove does not burn properly or the mix combustible/air is
not the right one try with this loading parameter.
9.6.2.
MENU 2. HEATING MANAGE
This menu manages the combustion parameters. It has
different submenus:
9.6.2.1.
BOILER THERMOSTAT
This menu allows to select the water temperature in the
boiler. You can select between 40º and 80º C, that is to say
the temperature you want your boiler to reach.
The selected value should be confirmed with the key
before going out of the menu.
When the water temperature of the boiler reaches the
requested value by the user, the boiler starts mode "stand
by", i.e. starts modulation lowing the power to adequate to
the selected temperature of the water and keep on working.
In this case it is possible that your house do not reach
the temperature requested from the external thermostat
because the water temperature value that you have fixed is
low for your comfort temperature. We recommend putting
an enough temperature value (70-75º) to allow the boiler
keep on working and reach your house comfort temperature
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
before going out of
before going out of the menu.
Auger Calibration
-2
-1
-7
Fan Calibration
-2
-1
-7
Boiler Thermostat
73
74
40
55
Power
P2
P3
P4
0
1
2
0
1
2
75
76
77
HYDROBOX, HYDROTEX AND HYDROCONFORT
7
7
80