9.4.
BOILER STATUS
With the boiler running, pushing only once the key
the boiler status.
9.5.
USER MODE
Below is a description of the display in normal operation depending on the available functions.
9.5.1.
BOILER SWITCH ON
To switch on the boiler we have to push the key
process will start; we will see the message "Ignition"
The time of lighting process is several minutes. If after this time the flame is not present the boiler will automatically show the alarm "Er12"
9.5.2.
BOILER RUNNING
Once smokes temperature reach the set up the boiler considers it is working, then will switch to "stabilization" during a few minutes before
ending the lighting process.
Once the stabilization process is finalized the boiler is in
mode "Run mode" represented by the normal working
mode. The display will show the time, date, working power,
water temperature, thermostat temperature and winter/
summer mode.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
in the display, we can access to the next menu which provides technical information of
T. Fumes
T. Water
900 ºC
ºC
Fan speed
Recipe
0 rpm
1 nr
during three seconds. First the boiler will make an initial "check up" and then the lighting
Tue 22 May 2018
Information
T. Ext
ºC
Item code 513
1001
IGNITION
Tue 22 May 2018
52
Pressure
0 mbar
RUN MODE
HYDROBOX, HYDROTEX AND HYDROCONFORT