1.9 Cable Properties and Connector Pinouts
1.9.1 Cable Installation
1. Mount the cable exit in the down or lower hemisphere region to promote drainage after washdown.
2. Create a drip loop.
This is so any liquids or chemicals that spray or splash on to the cable will travel down to the loop and drip off
instead of running down the cable directly on to the motor strain relief bushing.
Strain
Relief
Drip
Loop
l
l
CAUTION
The cable bushing could come loose or allow for contamination to get inside the motor,
if no strain relief on the cable is used.
This could lead to unexpected behavior of the motor and electrocution hazard due to
failure of electrical terminations.
AKMA Installation Manual | 1   English
Kollmorgen® | kdn.kollmorgen.com | June 2024
23