Operating Mode
The default state of the SCP is Operating mode. In Operating
mode, the SCP communicates with other Xanbus-enabled
devices and displays all the network information it is configured to
display.
Standby Mode
While in Standby mode, the SCP remains powered, "listening" and
reporting its status to the network. However, the output power of
all Xanbus-enabled devices is disabled and all inverting, charging,
and generator starting activity stops. Selecting Standby mode
stops the generator (if it is running and a Xanbus Automatic
Generator Start is part of the system) and puts the SCP (and all
Xanbus-enabled devices) into Standby mode.
40
When to use
Use Standby mode when you are adding or removing devices
from the network. Authorized service personnel must also put the
network in Standby mode before performing software upgrades
and diagnostics.
To put the power system into Standby mode:
1. On the System Settings menu, highlight "System Mode,"
and press Enter.
2. Select "Standby" and press Enter.
To return to Operating mode:
1. On the System Settings menu, highlight "System Mode,"
and press Enter.
2. Select "Operating" and press Enter.
Xanbus System Control Panel (SCP) Owner's Guide