Choosing a Location
Choose a location that allows unobstructed access to the SCP
screen and buttons.
The location should be indoors, dry, and free from corrosive or
explosive fumes.
EXPLOSION HAZARD
The SCP is not Ignition-Protected. Do not install in areas requiring
Ignition-Protected equipment, such as areas containing gasoline
engines, tanks, or fuel-line fittings.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
975-1171-01-01
WARNING
Installing the Xanbus Network
This section describes requirements for installing the SCP as part
of a Xanbus network-managed power system. For the system to
function properly, requirements for network layout and termination
must be followed.
Network Components
A Xanbus network consists of the following components:
Xanbus-enabled devices—these include the SCP, the
n
Schneider Electric Conext XW Pro inverter/charger,
Xanbus AGS, and MPPT Charge Controllers. The network
can support up twelve Schneider Electric Conext XW Pro
inverter/chargers, and up to twenty Xanbus-enabled
devices total. However, a typical Schneider Electric Conext
XW Pro system on one Xanbus network would require
fewer devices. For example: three inverter/chargers, two
charge controllers, one AGS and one SCP.
Xanbus power supply—the network requires a power
n
supply capable of providing 15 VDC/200 mA to each
device. The Schneider Electric Conext XW Pro provides
network power, but if no inverter/charger is installed, an
external power supply is required.
Xanbus cables—each Xanbus-enabled device is connected
n
by a standard straight-through Ethernet cable—CAT 5e.
See "Xanbus Cable" on the next page. These standard
cables can be purchased from any computer supply store.