Installing the Xanbus System Control Panel (SCP)
2 Installation
Chapter 2 contains information and procedures for planning and
installing the Xanbus System Control Panel (SCP).
It includes:
Installing the SCP
n
Installing the Xanbus Network
n
Mounting the SCP
n
Verifying the SCP
n
12
Installing the Xanbus System
Control Panel (SCP)
The Xanbus System Control Panel (SCP) is designed to be wall
mounted (see "Mounting the SCP" on page 17), and requires no
connections other than Xanbus network cables or a terminator
plugged into the back of the unit.
Because you cannot access the SCP network inputs once the
unit is mounted, the Xanbus cables must be routed through the
wall and connected before securing the SCP.
Materials and Tools Required
The following materials and tools are required to complete the
installation:
Mounting template sticker (supplied)
n
Mounting plate (supplied)
n
Mounting bracket (supplied)
n
Four #6 (M3), self-tapping screws (supplied)
n
Two #8 (M4), self-tapping screws (supplied)
n
Cable clamps or hardware fasteners
n
Xanbus network cables or equivalent (CAT 5 or CAT 5e
n
cable with RJ-45 connectors wired to T568A standard)
Two network terminators (one terminator is supplied with
n
the SCP and each Xanbus-enabled device)
Phillips head screwdriver
n
Jigsaw or small keyhole saw
n
Power drill with 1/8" bit (optional)
n
Xanbus System Control Panel (SCP) Owner's Guide