NOTICE
EQUIPMENT DAMAGE
Do not use crossover cable for the Xanbus network cable. On
crossover cable, the order of color-coded wires at each end of
the cable is different.
Failure to follow these instructions can result in equipment
damage.
Figure 4 Xanbus Cable
Network terminators ("Xanbus Network Terminators"
n
below)—the Xanbus network must be properly terminated
at each end with network terminators. If the network is not
properly terminated, signal quality is degraded and
performance on the network is reduced. Permanent
configuration without terminators is not supported. One
terminator is included with the SCP. Depending on your
14
network layout, this terminator may need to be inserted into
another device elsewhere in the network.
Figure 5 Xanbus Network Terminators
Xanbus System Control Panel (SCP) Owner's Guide