Interface DeltaSpot 1.10
Entrées
Entrée
pince de sou-
dage
E00
E01
E02
E03
E04
E05
E06
E07
E08
E09
E10
E11
E12
E13
E14
E15
E16
E17 - E19
E20
E21
E22
E23
E48 - E63
E64 - E95
E96 - E127
E128 - E143
E144 - E159
E160 - E175
Sorties
Sortie pince de
soudage
A00
A01
A02
A03
A04
A05
A06
92
Commentaire
start homing
start welding (no htr)
reset errors
main drive open
main drive close
tape drive forward (movable arm)
tape drive backward (movable arm)
tape drive forward (fixed arm)
tape drive backward (fixed arm)
tape length reset (movable arm)
tape length reset (fixed arm)
reset electrode service life (movable arm)
reset electrode service life (fixed arm)
reset lubrication
enable welding current
enable external position control
activate docking mode
expected gun code
reset sheet thickness calibration
record sheet thickness
save sheet thickness calibration
enable external position control (compensation drive)
program number
spot number
part serial number
target position
compensation drive target postion
sheet thickness
Commentaire
ready
error
warning
referenced
remote control connected
external position control active
manual mode

Publicité