SPECIFICATIONS
SubDrive 15 Connect/SubDrive 20 Connect
Specification
NEMA 3R (indoor/
Order Number
Voltage
Phase In
Frequency
Current (max)
Input from
Power Source
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Output to
Frequency Range
Motor
Current (max)
Wire Gauge Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature (at 230
Operating
VAC input)
Conditions*
Relative Humidity
Temperature
Storage**
Shelf Life
Dimensions
NEMA 3R (indoor/
and Weight
outdoor)
* Operating temperature is specified at full output power when installed as recommended. Refer to
"Over Temperature Foldback" on page
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
outdoor)
•
30-78 Hz: 1/2-rated pump (3-Phase)
•
30-70 Hz: 2/3 or 3/4-rated pump (3-
Phase)
•
30-60 Hz: Matched pump (3-Phase)
•
30-63 Hz (Single-Phase Motors)
10.4 A (single-phase 3–wire)
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : 11.8 kg)
36.
SubDrive 15 Connect/SubDrive 20 Connect
SubDrive 15
5870205103C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
12 A
4 Watts
2.5 kW
Refer to
"Input (Power) Wire and Fuse Sizing" on page
272 VAC Maximum
Single-Phase (3–wire) OR Three-Phase
5.9 A (three-phase)
Refer to
"Output (Motor) Wire Sizing" on page
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
Model
SubDrive 20
5870205313C
17.3 A
~ 0.95
5 Watts
4.2 kW
22.
•
30-78 Hz: 1/2-rated pump (3-Phase)
•
30-70 Hz: 2/3 or 3/4-rated pump (3-Phase)
•
30-60 Hz: Matched pump (3-Phase)
•
30-63 Hz (Single-Phase Motors)
•
60-156Hz: 1/2-rated pump (MagForce)
•
60-156Hz: 2/3 or 3/4-rated pump
(MagForce)
•
60-120Hz: Matched pump (MagForce)
8.1 A (three-phase)
13.2 A (single-phase 3-wire)
22.
9.75" x 16.9" x 5-1/4" : 19 lbs
(25 x 43 x 13 cm) : 8.6 kg)
SPECIFICATIONS
49