T T a a b b l l e e 2 2
( ( c c o o n n t t i i n n u u e e d d ) )
Display
Condition
Green Motor
High Pressure
Frequency
Green Motor
Audible
Frequency
Noises
No Display
None
FE Connect
Light On
Solid
Cannot Con-
nect to Drive
Bluetooth
FE Connect
Light Off
Green Motor
RFI-EMI
Frequency
Interference
System Regu-
lates but dis-
Green 199P
plays 199P
Possible Cause
Pressure sensor setting
Shorted sensor wire
Fan
Hydraulic
Plumbing
Display board cable discon-
nected or loose
Attempting to connect to in-
correct drive
Out of Wi-Fi range of drive
(more than 100 ft line-ofsite)
Wi-Fi timeout expired
Poor grounding
Wire routing
The pressure in the system is
199 psi or higher
Corrective Action
Adjust pressure sensor
Verify condition of sensor wire and repair.
Remove sensor wire at Pressure Input Board.
1. if drive stops running, wire may be shorted
2. if drive continues to run, replace Pressure Input Board
3. If drive continues to run after replacing Pressure Input board, re-
place drive
For excessive fan noise, replace fan
If fan noise is normal, drive will need to be relocated to a more remote
area
If a hydraulic problem, try raising or lowering depth of pump
Pressure tank location should be at entrance of water line into house
Verify cable connection between main control board and display
Ensure the Wi-Fi SSID (hotspot name) you are connecting to matches
the correct drive
Move so Wi-Fi signal is closer to the drive if walls or floors are between
you and the drive
Wi-Fi module not responding, cycle power to drive
Cycle Wi-Fi radio on mobile device, refresh Wi-Fi connection list
If more than fifteen (15) minutes since last power cycle, cycle power to
drive
If more than 1 hour since last disconnection from Wi-Fi, cycle power to
drive
Adhere to grounding and wire routing recommendations
An additional external filter may be needed.
The max pressure the display can show is 199 psi. Use the pressure
gauge or Wi-Fi / FE-Connect app to view the system pressure.
MAINTENANCE
Troubleshooting
47