Installation and operating instructions • Wilo-Atmos GIGA-I/-D/-B • Ed.01/2023-08
Property
Pipe and pressure measure-
ment connections
Permissible min./max. fluid
temperature
Ambient temperature during
operation min./max.
Temperature during storage
min./max.
Max. permissible operating
pressure
Insulation class
Protection class
Permissible fluids
Permissible fluids
Permissible fluids
Electrical connection
Electrical connection
Special voltage/frequency
PTC thermistor sensor
Speed control, pole
switchover
Speed control, pole
switchover
Table 2: Technical data
The detailed motor data as per EU2019/1781 can be consulted via the motor's article num-
ber here: https://qr.wilo.com/motors
Value
Flanges PN 16 in accordance
with DIN EN 1092-2 with
pressure measurement con-
nections Rp ⅛ in accordance
with DIN 3858.
Partially PN 25, depending on
the pump type
-20 °C ... +140 °C
0 °C ... +40 °C
-30 °C ... +60 °C
Up to DN 200:
16 bar (up to + 120 °C)
13 bar (up to + 140 °C)
(Version to -P4: 25 bar)
DN 250:
16 bar (up to + 140 °C)
F
IP55
Heating water in accordance
with VDI 2035 part 1 and part
2
process water
cooling/chilled water
water-glycol mixture up to
40 % vol.
Heat carrier oil
Other fluids (on request)
3~400 V, 50 Hz
3~380 V, 60 Hz
Pumps with motors with dif-
ferent voltages or other fre-
quencies are available on re-
quest.
Standard version from 5.5 kW Other motor power at addi-
Wilo control devices (e.g.
Wilo-CC-HVAC system)
Pole switchover
en
Note
Depending on fluid and op-
erating pressure (lower
temperatures partly on re-
quest as special version)
Lower or higher ambient
temperatures on request
Version ... -P4 (25 bar) as
special version at additional
charge (availability de-
pends on the pump type)
Standard version
Standard version
Standard version
Standard version
Special version or auxiliary
equipment (at additional
charge)
Special version or auxiliary
equipment (at additional
charge)
Standard version
(50 Hz version)
Partially standard version
(60 Hz version)
Special version or auxiliary
equipment (at additional
charge)
tional charge
Standard version
Special version or auxiliary
equipment (at additional
charge)
57