Evacuate the system tank. This can done be via the connection <29> for the manual diaphragm pump (see Ill. [5] on
page 38) or with a wet vacuum cleaner.
Unscrew cover of the service opening <30>
Make sure that the float switch of the level sensor  <27> and float switch rods are free from suspended matter
and solids, clean if necessary. In case of stubborn dirt, remove, clean and re-install
Make sure that the inlet opening of the wastewater pump
 <23> is free from suspended matter and solids, clean if
necessary. In case of stubborn dirt, remove, clean and re-install
Dismantling the pump:
• Unscrew screws <1>.
• Press off the wastewater pump at the press-off notches
<2> with a screwdriver if necessary
Make sure that the system tank is free from suspended matter and
solids, clean if necessary.
Make sure that the ventilation bores <31> are free from
suspended matter and solids, clean if necessary