Danger through incorrectly dimensioned connection cables. The lifting station is only designed for operation
with the enclosed connection cables (or equivalent). If in doubt, consult the manufacturer / supplier.
•
Fit end sleeves (length 8 mm) to the ends of the cables
•
Lay the connecting cable safely from the system tank to the control unit (e.g. conduit pipe, cable duct)
•
Attach connecting cable to the terminal strip acc. to the
circuit diagram (next page). To do so, keep the relevant cable
terminal <3> pressed down against the spring pressure with a
suitable screwdriver until the end of the cable has been inserted
•
Attach strain relief fittings for all connecting cables (tightening torque
0.5 Nm)
•
Connect battery plug to battery
•
Fit and fasten the housing cover,
tightening torque 1.2 Nm
•
Route the battery's cable (32) so that it does not cover
the LEDs or is clamped.