3.6
Installing the control unit
•
Select the mounting position making sure that:
– there is a safety socket in the direct vicinity of the control units.
– The connecting cable from the wastewater pump and float
switch can be installed correctly and routed to the control unit.
– The control unit can be fastened safely and sufficiently.
•
Unscrew the housing cover <5>
•
Break out the cable ducts <1> with a suitable tool
•
If an external potential-free contact (external alarm signal)
connection is provided for this installation, break out the cable duct
<1B>
•
Press the rubber grommets <2> into the openings <1>
•
Fit all three fastening screws (drilling template included in the
scope of delivery). Make sure that the gap <4> between the screw
heads and fastening area is approx. 3 to 4 mm
•
Suspend the control unit on the three fastening screws and press
down lightly