MN008454A01-AB
Chapter 8 : Analyzer Mode
If no keypad button is pressed for 10 minutes, the charger exits Analyzer Mode and returns to normal
message displays.
Pocket #xx is displayed in the upper left corner of the Display.
To return to Pocket 1 when displaying any other pocket, press OK for more than the Entry Time
selection.
8.2
Swapping Batteries in a Pocket
If a battery is removed and then the same or a different battery is inserted into the same pocket, the
parameter displayed for the second battery is the same parameter that was being displayed for the first
battery.
For example, Battery IMPRES 2 Cycles is being displayed for an IMPRES 2 battery. This battery
is removed from the pocket. A different IMPRES 2 battery is inserted into the same pocket. The first
parameter displayed for the second battery shows Battery IMPRES 2 Cycles.
The second battery may not have the parameter displayed for the first battery. In this case, the
identification message is displayed for the second battery.