Table 9: Charging Indications for IMPRES 2 Calibration-Calibration Initially Disabled, then Enabled
Status
Charger Powers On
Battery Detected
Requesting IMPRES 2 Battery
Calibration
Calibration is disabled in
charger.
Battery is charging
Battery Discharging
OK selected
Rapid Charging
Charged to 90 % or more
Charged to 95 % or more
Charger Display
IMPRES 2 CHARGER
IMPRES 2 BATTERY
WARNING: ENABLE
BATTERY CALI-
BRATION?
Press OK to ena-
ble calibration.
Ignore for normal
charging (mes-
sage disappears
after one minute).
CAL DISCHARGE xxxx0mAh
yyy%Ptl
CAL RAPID CHARGE
xxxx0mAh yyy%Ptl
CAL TRICKLE CHRGE
xxxx0mAh yyy%Ptl
CHARGE COMPLETE
xxxx0mAh yyy%Ptl
REPLACE BATTERY EX-
POSED OVERTEMP
MN008454A01-AB
Chapter 4 : Charger Overview
LED Indicator
Green for approximately one
second
Battery requires calibration,
but calibration is disabled in
charger: Alternating Amber
and Green for four seconds.
Steady Red
Steady Amber
Steady Red
Blinking Green
Battery Calibration successful:
Steady Green
Battery Calibration successful,
but may be nearing end of
service (battery is usable):
Blinking Red and Green
Battery calibration successful,
but battery has been exposed
to cumulative over tempera-
ture. Recommend to remove
23