Čeština
Kód
Obrazovka
alarmu
WARNING ADSORBER Low Electrical
A16
Heater Temperature Column 2
WARNING ADSORBER High Purge Air
A17
Temperature
WARNING ADSORBER High Dewpoint
A18
Temperature
ALARM FRIDGE High Compressor Dis-
A19
charge Temperature
WARNING ADSORBER Low Pressure
A20
Column 1
WARNING ADSORBER High Pressure
A21
Column 1
WARNING ADSORBER Low Pressure
A22
Column 2
WARNING ADSORBER High Pressure
A23
Column 2
A24
WARNING ADSORBER missing cooling
A25
ALARM FRIDGE Compressor Protection
ALARM FRIDGE Low Evaporation Tem-
A26
perature
ALARM FRIDGE Low Aux Evaporation
A27
Temperature
ALARM FRIDGE Low Pressure by Pre-
A28
ssure Switch
WARNING CHANGE
A30
FILTERS!!!
A31
CLOCK ALARM
ATT
ATT
ATT
Resetování
025-040
060-090
140-340
A, T>(požadovaná
X
X
X
hodnota odporu –
30 + 20) (**)
A, pokud T<98 °C
X
X
X
(**)
A, pokud T<(Set-
X
X
X
PDP + P32) -2 (**)
A
Nu
X
A
X
X
X
A
X
X
X
A
X
X
X
A
X
X
X
X
X
X
A
A
Nu
X
A
Nu
X
A
Nu
x
A
Nu
X
Resetování po aktu-
X
X
X
alizaci data údržby
X
X
X
ATT060-090
Prodleva
Podmínky způsobující aktivaci alarmu
600 s
AIN – Teplota profukovacího vzduchu
900 s
AIN – Měřič rosného bodu
600 s
AIN – Teplota vzduchu na výstupu z kompresoru
Okamžitě
DIN – Spínač A – tlak vzduchu
120 s
DIN – Spínač A – tlak vzduchu
120 s
DIN – Spínač B – tlak vzduchu
120 s
DIN – Spínač B – tlak vzduchu
120 s
DIN – Spínač ochrany kompresoru je aktivní
1 s
AIN – Teplota tepelně účinné látky
60 s
AIN – Ochrana Multicooleru – teplota tepelně účinné
60 s
DIN – Spínač nízkého tlaku chladiva je aktivní
60 s
1 mm
Skončila životnost fi ltrační vložky
Popis: Zkontrolujte nebo vyměňtě desku časovače –
Alarm resetujte vypnutím ovladače
Zastavení
kompresoru
Ne
Ne
Ne
Ano
Ne
Ne
Ne
Ne
Ne
Ano
Ano
Ano
látky
Ano
Ne
Ne
10 / 14
Zastavení
Relé alar-
sušičky
mu
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní
Ne
Aktivní