General technical data
Housing dimensions (L x W x H)
Weight of switch unit
Permissible temperature range
Mains standby (ready for operation) 14 mA
Mains current in operation
Protective class
Type of protection switchgear
Type of protection probe
Electrical connections suitable for
all copper conductors
Cable sheath diameter
Supply
Operating voltage
Mains connection
switch
Pre-fuse required
395-016
Technical data
180 x 200 x 70 mm
approx 1 kg
0 bis 50 °C
35 mA
I
IP 54
IP 68
0,08 - 2,5 mm
5 - 9 mm
230 V AC
1~
50 Hz ± 10% L / N
Safety plug on the
unit with 1.4 m
connection cable
max. C 16 A (provide on
installation side),
all-pole main switch in
the supply cable
62
Inputs
Sensor input
Outputs
Potential-free switch contact • Changeover contact: centre
Option: Signal generator
(Article-no. 20162)
SonicControl sensor input
contact; make contact; break
contact
• max. 42 VAC / 0.5 A
Connection possibility for an
external signal generator
2020/01