Incident display
Communication error
7.3 General faults:
Recognised fault
Deviation between the
grease layer depth in
inspection window and the
measured depth of grease
layer
395-016
Errors and Malfunction
Fault
Acoustic signal and flashing
Fault
Faulty function caused by
the faulty measurement
56
Cause
Faulty modem reception
Cause
- Faulty sensor installation
- Positioning during
installation
- Faulty initial initialisation
- Dirt deposited on the sensor
Remedy
Step 1: Check basic reception
possibility;
Step 2: If no reception is possible
then a modem cannot be used;
if reception is basically possible,
replace the modem
Remedy
- Tighten the cable a little and
then tighten the screw
connection by hand
- Take the type of separator
into account
- Re-calibration of the sensor
- Check the position of the
sensor
- Set the type of grease
- Set the type of grease and
clean the sensor