Please heed the safety instructions in chapter 1.
The switch unit must be completely disconnected from the mains
for cleaning. When replacing the batteries, use 9-V Block. Repairs
may only be carried out by the manufacturer.
The switch unit does not require any maintenance.
The connection cables must be checked for damage. If any dam-
age can be detected, the system must be put out of operation
immediately.
The sensor has to be cleaned at regular intervals.
Every time disposal takes place the sensor must be cleaned with
warm/hot water*. When a high-pressure jet cleaner is used, main-
The control unit will only display a grease thickness layer 24 hours after being placed into operation due to the fact that the reading
is taken at night, "-" will be displayed until then.
395-016
Inspection and Maintenance
53
tain a safe distance of 30 cm. The sensor does not have to be
removed for cleaning.
The sensor does not have to be removed for cleaning. The grease
separator must be filled with water after emptying.
* In the case of KESSEL EasyClean free grease separators
systems Auto Mix, Mix & Pump- and Auto Mix & Pump, clean-
ing can wait until the next servicing date since the separator is
cleaned with warm water. If necessary (heavy sensor soiling by
strong hardening grease) carry out cleaning every time disposal
is carried out.