3.1 ELECTRIC INSTALLATION

ALL ELECTRICAL CONNECTIONS SHALL
BE
PERFORMED
TECHNICIAN. ALL SERVICE MUST BE
PERFORMED
SERVICE TECHNICIAN.
Check on the plate of the machine that the
electrical specifications of the power source are
the same as the machine.
The machine uses 400VAC, 50-60Hz, 3Ph, 8.2 Amp.
Electrical specifications are clearly marked on a
label at the end of the electric cord.
Before connecting the machine to the power
source, check that the power supply has an
efficient grounding system.
Connect the electric cable of the machine with an
approved plug.
NOTE:
The outlet installation must be verified by a licensed
electrician before connecting the tire changer.
NOTE:
The yellow with green wire in the cord is the
grounding wire.
Never connect the grounding wire to a live terminal.
Check that the power supply has an automatic
circuit breaker with a differential circuit set at 30 mA.
The electric motor operates in a wide voltage range
(plus 10% - minus 7%) and frequency range (50 or 60
cycles) and has a class of insulation suitable for hot
and moist climates.

3.2 MOTOR ROTATION CHECK

Once the machine is hooked-up, turn the machine
on using the ON/OFF switch.
Ensure that the rotation direction of the pump is the
same as indicated by the arrow on the motor cover.
If not, reverse any two phase cables on the plug (i.e.
reverse the brown and the blue cable).
ANY DAMAGE CAUSED BY THE NON
APPLICATION
INSTRUCTIONS SHALL NOT BE DEBITED
TO THE MANUFACTURER AND WILL
VOID THE WARRANTY.
HOFMANN behält sich das Recht zu Änderungen ohne Vorankündigung vor _ HOFMANN reserves the right of modification without notice _ Document non contractuel
monty 3650
Betriebsanleitung Operator's Manual Notice d' utilisation
BY
A
LICENCED
BY
AN
AUTHORIZED
OF
THE
ABOVE
Modéle: monty 3650 _DE-EN-FR_ Release December 2018