7. TroUBLE SHooTiNG
For Aquila Audax M see the manual 4-119427.
Avoid personal injery or death.
The "Spare parts" handbook does not authorise the user to carry out any work on
the machine other than the operations specifically described in the User Manual,
and is only intended to enable the user to provide the technical assistance service
with precise information in order to minimise response times.
Power cord conductor shorting to ground.
➥ Check the wiring.
Motor shorted.
➥ Renew the motor.
➥ Replace motor-inverter unit circuit board.
➥ Check pedal unit microswitch.
Belt broken.
➥ Replace belt.
rotation control pedal fails to return to the central position
control spring broken.
➥ Renew the spring.
No vertical travel
➥ Check for bent hoses.
➥ Check operation of raising-lowering valve.
➥ Check for jammed rollers.
Bead breaker unit is underpowered, it does not break the bead
Perform the checks in the previous point: "Bead breaker unit not working".
cylinder seals worn.
➥ Renew seals.
➥ Renew bead breaker cylinder.
Bead breaker cylinder leaks air around the rod
Air seal worn.
➥ Renew seals.
➥ Renew bead breaker cylinder.