5. Technical Specifications/Certifications

5.1 Technical Specifications

WEIGHT
7.9 oz. (instrument with battery and clip)
DIMENSIONS
4.4 x 3.00 x 1.37 inches – without fastening clip
(L x W x H)
ALARMS
Four gas alarm LEDs, a charge status LED, an audible alarm,
and a vibrating alarm
VOLUME OF
95 dB typical
AUDIBLE
ALARM
DISPLAY
LCD display
BATTERY TYPE
Rechargeable Li polymer battery.
Li polymer battery must not be charged in Ex area
INSTRUMENT
24 hours at 77°F (25°C)
RUN TIME
CHARGING TIME ≤ 4 hours
The maximum safe area charging voltage
Um = 6.7 Volts D.C
TEMP RANGE
14
to 104°F
-4
to 122°F
50
to 95°F
-40 to +140°F (-40 to 60°C)
-40 to +129°F (-40 to 54°C)
HUMIDITY
15 - 90% relative humidity, non-condensing;
RANGE
5 - 95% RH intermittent
ATMOSPHERIC
800 to 1200 mbar
PRESSURE
RANGE
INGRESS
IP 67
PROTECTION
MEASURING
Combustible gas: Catalytic sensor
METHODS
O 2 and Toxic gas: Electrochemical sensor
MEASURING
Combustible
RANGE
0-100% LEL
0-5.00% CH 4
(-10 to 40°C)
Normal operating range
(-20 to 50°C)
Extended operating range
(10 to 35°C)
While charging battery
Intrinsic safety
ambient temperature range
(ATEX, IEC)
Intrinsic safety
ambient temperature range
(CSA, ETL)
O 2
CO
0-30% Vol. 0-1999 ppm
H 2 S
0-200 ppm
5-1