Activating the switch contact via the transponder and user
PIN code
Hold the user transponder against the code lock and enter the
corresponding user PIN code to switch the relay. The relay only
switches if a saved combination of a user transponder and PIN
code for opening the lock is used.
Switching the relay via a user transponder
Hold a user transponder against the keypad (1) on the code
lock. If a valid user transponder is detected by the code lock, the
changeover contact will be activated.
In this access mode, the relay does not switch when a valid user
ID is entered.
To set this access mode, proceed as follows:
The code lock must be in standby mode and the LED
indicator (2) must be red.
Enable programming mode (see section 10 "Programming",
paragraph "b) Enabling/exiting programming mode"). The
LED indicator (2) will then flash red.
Example:
Press the
Enter one of the following values for the desired access
mode:
0 = Access via transponder or user ID (default setting)
1 = Access via transponder and user PIN code
2 = Access via transponder
key. The LED indicator (2) will turn yellow.