2. How to use
Main control
The display shows the main control by default. The current status is displayed and by tapping on
the touch screen you get access to various submenus and functions.
Display informations (fig. A1)
Pos.
Function
1
Status display, top
2
User menu
3
Applications
4
Flow display
5
Temperature display
6
Status display, bottom
7
Main menu
8
Temperature setting
Temperature display
The coloured scale ring fills up as the temperature setting is increased and the colour changes
from blue when the temperature is low to red when the
temperature is high. In addition, the target temperature is displayed in °C as a figure in the mid-
dle of the display.
Temperature setting
The desired temperature can be selected by tapping on
dragging along the coloured scale ring for a quick selection within a range of 20 °C to 60 °C.
Tapping
or
once changes the temperature by 1 °C, in the comfort range between 35
and 43 °C by 0.5 °C. If the temperature is set below 20 °C, the symbol
perature display and the appliance switches off the heating function.
Temperature quick selection
A short tap on the temperature value opens the selection window for stored temperatures. A
total of six temperatures are preset and can be assigned their own values. By briefly tapping on
the respective temperature field, the temperature is set as the setpoint. To save your own tem-
perature, change the setpoint to the desired value using
to reopen the selection window and then long tap on the memory location that is to be changed.
The memory field flashes green briefly to confirm.
User menu
Up to eight user profiles can be created. Every user has the option to save his desired tempera-
tures for the different uses in a profile. The user profiles can be selected by tapping on the profile
image (fig. A3) and the temperatures saved in the profile are set. By tapping on
can be created and then configured..
Applications
Preset applications can be selected here. Simply tap on the desired symbol (fig. A4).
The temperatures set at the factory (
handwash = 35 °C,
bath = 40 °C,
hot water = 48 °C) can be changed for each application via the tempera-
ture setting. If you touch the application symbol for 3 seconds, the current temperature is saved
for the selected application. The application icon flashes green briefly to confirm.
Flow display
The maximum hot water flow can be defined by the user. Briefly tapping on the flow rate display
opens the selection menu (Fig. A5). Select the desired flow rate and confirm with .
Status display, top
Control lock active (PIN)
The inlet temperature exceeds the target value (appliance does not heat up)
Indication of activated Wi-Fi. The amount of bars indicates the signal strength
Indication of activated Bluetooth
Indication of a successful connection to CLAGE Cloud
Status display, bottom
Display area for functions which require confirmation from the user or which are of great signifi-
cance.
Main menu
All function menus and saved values of the appliance can be selected from here. Tap on the
symbol to go back to the main control (fig. A6).
For further informations please use the online operation and installation
instruction. Please follow the link below or use the QR code via smart-
phone or tablet.
https://www.clage.de/links/gma/DSX-Touch-GMA-9120-34485
and
for the fine setting or by
Venting after maintenance work
appears in the tem-
1.
and
, briefly tap on the setpoint
2. Unscrew the jet regulator on the outlet fitting and open the cold water tap valve to rinse out
3. Open and close the hot water tap until no more air emerges from the pipe and all air has
4. Only then should you re-connect the power supply again (e.g. via activating the fuses) to the
, a new profile
5. The appliance activates the heater after approx. 10 seconds of continuous water flow.
Cleaning and maintenance
shower = 38 °C,
•
•
11
Eco active: The symbol indicates that the appliance is working with energy-saving set-
tings. (This means that the current energy consumption is in the energy-saving range
depending on the selected temperature and flow rate).
Maintenance: Tap the symbol to open a status message with additional information.
Maximum temperature reached: The temperature cannot be increased any further
since the set temperature limit has been reached. The temperature limit can be
changed in the main menu under "Settings".
Heating activated: As soon as the appliance heats water, this symbol appears.
Power limit: The full output of the instantaneous water heater does not suffice to heat
the tapped quantity of water to desired temperature. Reduce the flow via the flow
display.
This instantaneous water heater features an automatic air bubble pro-
tection to prevent it from inadvertently running dry. Nevertheless, the
appliance must be vented before using it for the first time. Each time the
appliance is emptied (e.g. after work on the plumbing system, if there is
a risk of frost or following repair work), the appliance must be re-vented
before it is used again.
Disconnect the instantaneous water heater from the mains (e.g. via deactivating the
fuses).
the water pipe and avoid contaminating the appliance or the jet regulator.
been eliminated from the water heater.
instantaneous water heater and screw the jet regulator back in.
Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use abrasive or
chlorine-based cleaning agents or solvents.
For a good water supply, the outlet fittings (e.g. jet regulators and shower heads) should be
unscrewed and cleaned at regular intervals. Every three years, the electrical and plumbing
components should be inspected by an authorised professional in order to ensure proper
functioning and operational safety at all times.
CLAGE