Télécharger Imprimer la page

Minebea Intec EC1XS Serie Installation Et Conseils De Sécurité page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

– YPS05-ZD (non-hazardous area)
– YPS05-XD (hazardous area)
§ To open the display and control
§ Remove the protective cap from the
§ Guide the cable with the pre-installed
§ Install cable gland on the housing in
§ Tighten the cable gland nut on the
!
§ Plug in the male connector on
§ Position the cover on the display
§ Replace the hexagonal nuts (7 mm).
8
Installation
Power Supply
The scale is powered by one of the
following power supplies:
or
Note:
Observe all warnings and safety
precautions. Unplug the power cord
from the wall socket (mains) before
performing any work on the equip-
ment. Installation work that affects
the IP65 or IP68 protection rating
must be performed with extreme
care. Any installation work that does
not conform to the instructions in
this manual will result in forfeiture of
all claims under the manufacturer's
warranty.
DC Connection on the EC1XS.-......-L
unit housing, remove the hexagonal
nuts (7 mm) and remove the screws.
bore hole on the indicator.
Note:
Keep the seal and nut in a safe place.
cable gland through the bore hole.
accordance with industry standards.
inside of the housing. Use a torque
wrench and tighten the cable gland
to 3 Nm.
Check the torque at appropriate
intervals to avoid over-tightening.
the pin terminal.
and control unit.
Check the fit of the seal between
cover and housing before closing
the display and control unit.
Replace any defective seals.
Use a torque wrench and tighten the
screws to 1.6 Nm.
Connecting the Built-in
RS-232 Interface
§ Open the display and control unit
housing.
1
§ Remove the protective cap.
§ Connect the cable to pins 1 through
6 in accordance with industry
standards (see Drawing No. 65710-
740-52-A4, Sheet 2).
§ Install the cable gland in accordance
with industry standards.
§ Position the cover on the display and
control unit. Replace the hexagonal
nuts (7 mm).
Connecting the Optional
RS-422 Interface
§ Open the display and control unit
housing.
1
§ Remove the protective cap.
§ Install the RS-422 interface card as
shown in the illustration on the left.
§ Connect the cable from the interface
card to the main PCB (see illustration).
§ Install the cable gland in accordance
with industry standards.
§ Connect the cable to pins 1 through
10 in accordance with industry
standards (see Drawing No. 65710-
740-52-A4, Sheet 4).
§ Position the cover on the display
and control unit.
Replace the hexagonal nuts (7 mm).
Connecting the Optional Foot Switch
§ Open the display and control unit
housing.
1
1
§ Remove the protective cap.
5
6
§ Cut the round male connector off
of the model YPE05-S foot switch.
§ Remove the insulation from
a segment of the cable
§ Connect the cable gland (part no.
YAS04CIS) in accordance with
industry standards. Make sure the
shield has contact to the cable gland.
§ Connect the cable to the LV1
terminal strip on pins 5 and 6 in
accordance with industry standards.
Note:
Because the device is a simple switch,
transposing the wires will not affect
the function.
5
6
§ Install the cable gland in accordance
with industry standards.
§ Position the cover on the display and
control unit. Replace the hexagonal
nuts (7 mm).
!
Any sockets or ports on the display
and control unit to which no cable is
connected must be protected within
hazardous areas by affixing a cap
with the required IP protection rating.

Publicité

loading