5.2.2 Connection
Electrical connection
WARNING! Hazard via electrical current!
Improper installation of the device may result in injuries! Before installation,
compare the parameters of the local power grid with the specifications on the
device's rating table.
Only connect the device in case of full compliance!
Prior to connecting the device to a power source, ensure that the voltage and
o
frequency values on the rating table are consistent with the existing electrical
installations.
Voltage tolerance is ± 10%.
•
The device must be connected to both groundings whose ratings adhere to those in
the relevant regulations. The button is located at the rear of the device
•
The electrical socket circuit must be secured to a minimum of 16A. Connect the
device directly to a wall socket, do not use splitters or power strips.
•
Place the device so that the plug is easily accessible to quickly disconnect the device
if the need arises.
Water connection
•
A potable water connection must be located at the rear of the device.
•
Prior to connecting the device, pour in enough water to remove any remaining dirt
that may have entered the magnetic valves.
•
To ensure the device's uninterrupted operation, prevent the formation of limescale in
the chamber. To do so, use water with a hardness of 0.5 to 5° F. For harder water,
install a water softener.
•
Connect a pressure hose to the inflow pipe (3/4˝) located at the rear of the device.
Connect the other end of the pressure hose to the cold water installation using the
stopcock.
•
The water supply should have a pressure value
between 50kPa (0.5 bar) and 200kPa (2 bars).
If the entry pressure exceeds 200 kPa (2 bars),
install a pressure reducer.
- 30 -
.